Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system

73Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives. The purpose of this study was to determine the relation between clinical variables and the defibrillation threshold by using a standardized testing protocol and a uniform implantable defibrillator system. Background. Past studies have not revealed useful correlations between clinical variables and the energy required to terminate ventricular fibrillation. Most of these studies did not use a uniform implantable defibrillator system or a standardized protocol to measure the defibrillation threshold and, thus, did not control for the influence of these technical influences. We postulated that defibrillator and defibrillation threshold measurement-based sources of variability overshadowed important clinical predictors. Methods. The defibrillation threshold was measured by using a standardized protocol in 101 consecutive patients. We used a transvenous unipolar pectoral defibrillation system that employed a single endocardial right ventricular defibrillation coil as the anode and the shell of an 80-cm3 pulse generator as the cathode to deliver a 65% tilt biphasic pulse. Results. Several clinical variables were found to be significantly associated with the defibrillation threshold: patient gender, height, weight, body surface area, heart rate at rest, QRS and corrected QT (QTc) intervals, left ventricular mass and several measures of heart and chest size by chest roentgenogram. None of these variables had a correlation coefficient >0.45 with the defibrillation threshold. On multivariate analysis, left ventricular mass and heart rate at rest were the only independent predictors of the defibrillation threshold and explained only 25% of the observed variability. Conclusions. Despite the use of a uniform transvenous defibrillation system and a standardized protocol to measure the defibrillation threshold, no clinically relevant correlation was found between clinical variables and the defibrillation threshold. The defibrillation threshold is probably a function of a complex interaction of anatomic, physiologic and cellular variables that are not adequately represented by easily obtainable clinical information. It is probably not possible to predict defibrillation outcome from standard clinical variables. © 1995 American College of Cardiology.

Cite

CITATION STYLE

APA

Raitt, M. H., Johnson, G., Lee Dolack, G., Poole, J. E., Kudenchuk, P. J., & Bardy, G. H. (1995). Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system. Journal of the American College of Cardiology, 25(7), 1576–1583. https://doi.org/10.1016/0735-1097(95)00093-J

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free