The study presents combustion and emission results obtained using two serial pellet boilers of the same heating capacity 40 kW. These boilers have been designed by producers for domestic conditions of exploitation. The principal difference between boilers was the type of the burner. The study concerns the efficiency and ecological performance difference between burners of circular and rectangular forms. The features of the combustion process in both types of burners were studied when boiler operated with different sorts of pellets. The results suggest that the burner of circular form excels the rectangular form burner. However, there is some difference of NOx emission between circular and rectangular burners.
CITATION STYLE
Rastvorov, D. V., Osintsev, K. V., & Toropov, E. V. (2017). Influence of burner form and pellet type on domestic pellet boiler performance. In IOP Conference Series: Earth and Environmental Science (Vol. 87). Institute of Physics Publishing. https://doi.org/10.1088/1755-1315/87/3/032034