Objective: The objective of this study was to report the item response theory (IRT) calibration of an 18-item bank to measure general physical function (GPF) in a wide range of conditions and evaluate the validity of the derived scores. Methods: All 18 items were administered to a large sample of patients (n=2337) who responded to the items in the context of their outpatient rehabilitation care. The responses, collected 1997-2000, were modeled using the graded response model, an IRT model appropriate for items with two or more response options. Inter-item consistency was evaluated based on Cronbach's alpha and item to total correlations. Validity of scores was evaluated based on known-groups comparisons (age, number of health problems, symptom severity). The strength of a single, general factor was evaluated using a bi-factor model. Results were used to evaluate IRT assumption and as an indicator of construct validity. Local independence of item responses was also evaluated. Results: Response data met the assumptions of unidimensionality and local independence. Explained common variance of a single general factor was 0.88 (omega hierarchical =0.86). Only two of the 153 pairs of item residuals were flagged for local dependence. Inter-item consistency was high (0.93) as were item to total correlations (mean =0.61). Substantial variation was found in both IRT location (difficulty) and discrimination parameters. All omnibus known-groups comparisons were statistically significant (p<0.001). Conclusion: Item responses fit the IRT unidimensionality assumptions and were internally consistent. The usefulness of GPF scores in discriminating among patients with different levels of physical function was confirmed. Future studies should evaluate the validity of GPF scores based on an adaptive administration of items.

Cite

CITATION STYLE

APA

Cook, K., Kallen, M., Hayes, D., Deutscher, D., Fritz, J., Werneke, M., & Mioduski, J. (2017). Calibration and validation of an item bank for measuring general physical function of patients in medical rehabilitation settings. Patient Related Outcome Measures, Volume 9, 11–16. https://doi.org/10.2147/prom.s148788

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free