Validation of a Modified National Eye Institute Grading Scale for Corneal Fluorescein Staining

14Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Validation of the novel Lexitas modified NEI scale for use in assessment of corneal fluorescein staining. Patients and Methods: A series of 18 illustrations and 14 clinical photographs depicting varying severity levels of corneal fluorescein staining were assessed by 3 independent examiners. Regions of the cornea were graded for staining severity based on 3 different grading scales: the original NEI staining scale (density-based scoring; 0–3 scale), a structured version of the NEI scale (dot-count scoring; 0–3 scale), and the Lexitas modified NEI staining scale (0–4 scale with half-point increments). Kappa statistics (simple and weighted) were computed to determine intra-examiner image grading repeatability for each examiner over 2 separate assessments. Inter-examiner assessment reliability utilized the scores from the first read of each examiner, and pairs of examiners to compute kappa statistics. Results: Data was analyzed from the scores provided by the examiners from each gradable corneal region on 32 images (18 illustrations and 14 photographs) for a total of 154 corneal regions across the 3 grading scales for each validation run. The mean intra-examiner simple/weighted kappa values using the NEI density, NEI dot count, and the Lexitas modified NEI staining scales were 0.67/0.72, 0.91/ 0.94, 0.80/0.92 for the graded illustrations, and 0.83/0.88, 0.76/0.85, 0.77/0.88 for the graded photographs, respectively. The mean inter-examiner simple/weighted kappa values using the NEI density, NEI dot count, and the Lexitas modified NEI staining scales were 0.59/ 0.65, 0.86/0.90, and 0.78/0.91 for the graded illustrations, and 0.80/0.88, 0.84/0.89, 0.69/0.88 for the graded photographs, respectively. Conclusion: The expanded scale of the Lexitas modified NEI staining scale demonstrated a high degree of reliability and repeatability of grading assessments within and across individual examiners, comparing favorably with the original NEI staining scale. A future investigation into the in-office utility of the Lexitas modified NEI staining scale is warranted.

Cite

CITATION STYLE

APA

Sall, K., Foulks, G. N., Pucker, A. D., Ice, K. L., Zink, R. C., & Magrath, G. (2023). Validation of a Modified National Eye Institute Grading Scale for Corneal Fluorescein Staining. Clinical Ophthalmology, 17, 757–767. https://doi.org/10.2147/OPTH.S398843

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free