Teaching tracheal intubation: Airtraq is superior to Macintosh laryngoscope

14Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Tracheal intubation with Macintosh laryngoscope is taught to medical students as it is a lifesaving procedure. However, it is a difficult technique to learn and the consequences of intubation failure are potentially serious. The Airtraq optical laryngoscope is a relatively novel intubation device, which allows visualization of the glottic plane without alignment of the oral, pharyngeal, and tracheal axes, possessing advantages over Macintosh for novice personnel. We introduced a teaching mode featured with a progressive evaluation scheme for preparation and performance of tracheal intubation with medical students in this prospective randomized crossover trial who had no prior airway management experience to find the superior one. Methods. Twenty-six medical students of the 8-year programme in the 6th year participated in this trial, when they did their one-week rotation in the department of anaesthesiology. Each of the students intubated 6 patients, who were scheduled for surgeries under general anaesthesia, each laryngoscope for 3 patients respectively. One hundred and forty-nine consecutive patients scheduled for surgical procedures requiring tracheal intubation were enrolled. Patients were randomly allocated to undergo tracheal intubation using Macintosh (n = 75) or Airtraq (n =74) laryngoscope. The progressive evaluation scheme was applied to each intubation attempt. Results: Intubation success rate was significantly higher in Airtraq group than Macintosh group (87.8% vs. 66.7%, P < 0.05). Duration of glottis exposure was significantly shorter in Airtraq group compared to Macintosh group (50 ± 19 s vs. 81 ± 27 s, P < 0.001). A grade I Cormack and Lehane glottic view was obtained in 94.6% of patients in the Airtraq group versus 32% of patients in the Macintosh group (P <0.001). Duration of intubation in Airtraq group was significantly shorter (68 ± 21 s vs. 96 ± 22 s, P < 0.05) compared to Macintosh group. Conclusions: Airtraq laryngoscope is easier to master for novice personnel with a higher intubation success rate and shorter intubation duration compared with the Macintosh laryngoscope. Trial registration. Trial registration number is ChiCTR-TRC-13003987, approval date Dec 12, 2013. © 2014 Zhao et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Zhao, H., Feng, Y., & Zhou, Y. (2014). Teaching tracheal intubation: Airtraq is superior to Macintosh laryngoscope. BMC Medical Education, 14(1). https://doi.org/10.1186/1472-6920-14-144

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free