Balanced Ratio of Concrete Beams Internally Prestressed with Unbonded CFRP Tendons

12Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The compression or tension-controlled failure mode of concrete beams prestressed with unbonded FRP tendons is governed by the relative amount of prestressing tendon to the balanced one. Explicit assessment to determine the balanced reinforcement ratio of a beam with unbonded tendons (ρpfbU) is difficult because it requires a priori knowledge of the deformed beam geometry in order to evaluate the unbonded tendon strain. In this study, a theoretical evaluation of ρpfbU is presented based on a concept of three equivalent rectangular curvature blocks for simply supported concrete beams internally prestressed with unbonded carbon-fiber-reinforced polymer (CFRP) tendons. The equivalent curvature blocks were iteratively refined to closely simulate beam rotations at the supports, mid-span beam deflection, and member-dependent strain of the unbonded tendon at the ultimate state. The model was verified by comparing its predictions with the test results. Parametric studies were performed to examine the effects of various parameters on ρpfbU.

Cite

CITATION STYLE

APA

Lee, C., Shin, S., & Lee, H. (2017). Balanced Ratio of Concrete Beams Internally Prestressed with Unbonded CFRP Tendons. International Journal of Concrete Structures and Materials, 11(1), 1–16. https://doi.org/10.1007/s40069-016-0171-6