Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation

0Citations
Citations of this article
4Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. Methods: This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. Results: In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was − 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and − 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. Conclusions: The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

Cite

CITATION STYLE

APA

McNeely, R. N., Moutari, S., Pazo, E., & Moore, J. E. (2018). Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation. Eye and Vision, 5(1). https://doi.org/10.1186/s40662-018-0103-4

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free