Reliability of a point-of-care device for international normalized ratio testing during the three surgical phases of orthotopic liver transplantation: a retrospective observational study

5Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To investigate the reliability of a point-of-care device, the HEMOCHRON® Jr. Signature, for measuring the international normalized ratio (INR) during the three surgical phases of liver transplantation. Methods: A retrospective review was performed on patients undergoing liver transplantation during July to December 2013. Thirty-one patients who had simultaneous laboratory and point-of-care INR readings from each phase of liver transplant surgery (paleohepatic, anhepatic, and neohepatic) were eligible for inclusion. Bland-Altman analysis, Spearman’s rank correlation, and four quadrant plots were used to compare INR results from the point-of-care device (pocINR) with those from the laboratory (labINR). Results: Based on the Bland-Altman analysis, mean biases (95% prediction interval) were 0.10 (0.03 to 0.17), 0.19 (0.12 to 0.27), and 0.21 (0.01 to 0.43) for the paleohepatic, anhepatic, and neohepatic phases, respectively. The pocINR device showed a systematic underestimation of the labINR. The Spearman’s rank correlation coefficients (95% confidence interval [CI]) were: Ρ = 0.90 (95% CI 0.80 to 0.95); Ρ = 0.92 (95% CI 0.71 to 0.93); and Ρ = 0.71 (95% CI 0.46 to 0.85), respectively. Direction-of-change analysis between the paleohepatic to anhepatic and the anhepatic to neohepatic phases showed strong concordance of 84% and, also considering the small bias between the measurements, supports the use of the pocINR device in the clinical management of liver transplant surgery. Conclusion: Point-of-care INR was accurate prior to hepatic reperfusion, but reliability decreased in the neohepatic phase.

Cite

CITATION STYLE

APA

Mace, H. S., Lightfoot, N. J., Cordero-Rochet, M. J., Srinivas, C., Karkouti, K., & McCluskey, S. A. (2015). Reliability of a point-of-care device for international normalized ratio testing during the three surgical phases of orthotopic liver transplantation: a retrospective observational study. Canadian Journal of Anesthesia, 62(3), 258–264. https://doi.org/10.1007/s12630-014-0283-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free