CNN-based CP-OCT sensor integrated with a subretinal injector for retinal boundary tracking and injection guidance

  • Lee S
  • Kang J
12Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Significance: Subretinal injection is an effective way of delivering transplant genes and cells to treat many degenerative retinal diseases. However, the technique requires high-dexterity and microscale precision of experienced surgeons, who have to overcome the physiological hand tremor and limited visualization of the subretinal space. Aim: To automatically guide the axial motion of microsurgical tools (i.e., a subretinal injector) with microscale precision in real time using a fiber-optic common-path swept-source optical coherence tomography distal sensor. Approach: We propose, implement, and study real-time retinal boundary tracking of A-scan optical coherence tomography (OCT) images using a convolutional neural network (CNN) for automatic depth targeting of a selected retinal boundary for accurate subretinal injection guidance. A simplified 1D U-net is used for the retinal layer segmentation on A-scan OCT images. A Kalman filter, combining retinal boundary position measurement by CNN and velocity measurement by cross correlation between consecutive A-scan images, is applied to optimally estimate the retinal boundary position. Unwanted axial motions of the surgical tools are compensated by a piezoelectric linear motor based on the retinal boundary tracking. Results: CNN-based segmentation on A-scan OCT images achieves the mean unsigned error (MUE) of ∼3 pixels (8.1 μm) using an ex vivo bovine retina model. GPU parallel computing allows real-time inference (∼2 ms) and thus real-time retinal boundary tracking. Involuntary tremors, which include low-frequency draft in hundreds of micrometers and physiological tremors in tens of micrometers, are compensated effectively. The standard deviations of photoreceptor (PR) and choroid (CH) boundary positions get as low as 10.8 μm when the depth targeting is activated. Conclusions: A CNN-based common-path OCT distal sensor successfully tracks retinal boundaries, especially the PR/CH boundary for subretinal injection, and automatically guides the tooltip’s axial position in real time. The microscale depth targeting accuracy of our system shows its promising possibility for clinical application.

References Powered by Scopus

U-net: Convolutional networks for biomedical image segmentation

65039Citations
N/AReaders
Get full text

Optical coherence tomography - Principles and applications

1828Citations
N/AReaders
Get full text

Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation

663Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Development and ex-vivo validation of 36G polyimide cannulas integrating a guiding miniaturized OCT probe for robotic assisted subretinal injections

6Citations
N/AReaders
Get full text

Convolutional neural network-based common-path optical coherence tomography A-scan boundary-tracking training and validation using a parallel Monte Carlo synthetic dataset

4Citations
N/AReaders
Get full text

Handheld motorized injection system with fiber-optic distance sensors and adaptive time-delay controller

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lee, S., & Kang, J. U. (2021). CNN-based CP-OCT sensor integrated with a subretinal injector for retinal boundary tracking and injection guidance. Journal of Biomedical Optics, 26(06). https://doi.org/10.1117/1.jbo.26.6.068001

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

90%

Researcher 1

10%

Readers' Discipline

Tooltip

Engineering 6

67%

Nursing and Health Professions 1

11%

Physics and Astronomy 1

11%

Agricultural and Biological Sciences 1

11%

Save time finding and organizing research with Mendeley

Sign up for free