Derivation and validation of a novel right-sided heart failure model after implantation of continuous flow left ventricular assist devices

188Citations
Citations of this article
123Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: The aim of the study was to derive and validate a novel risk score for early right-sided heart failure (RHF) after left ventricular assist device implantation. METHODS: The EUROMACS (European Registry for Patients with Mechanical Circulatory Support) was used to identify adult patients undergoing continuousflow left ventricular assist device implantation with mainstream devices. Eligible patients (n=2988) were randomly divided into derivation (n=2000) and validation (n=988) cohorts. The primary outcome was early (<30 days) severe postoperative RHF, defined as receiving short- or long-term right-sided circulatory support, continuous inotropic support for ≥14 days, or nitric oxide ventilation for ≥48 hours. The secondary outcome was all-cause mortality and length of stay in the intensive care unit. Covariates found to be associated with RHF (exploratory univariate P<0.10) were entered into a multivariable logistic regression model. A risk score was then generated using the relative magnitude of the exponential regression model coefficients of independent predictors at the last step after checking for collinearity, likelihood ratio test, c index, and clinical weight at each step. RESULTS: A 9.5-point risk score incorporating 5 variables (Interagency Registry for Mechanically Assisted Circulatory Support class, use of multiple inotropes, severe right ventricular dysfunction on echocardiography, ratio of right atrial/ pulmonary capillary wedge pressure, hemoglobin) was created. The mean scores in the derivation and validation cohorts were 2.7±1.9 and 2.6±2.0, respectively (P=0.32). RHF in the derivation cohort occurred in 433 patients (21.7%) after left ventricular assist device implantation and was associated with a lower 1-year (53% versus 71%; P<0.001) and 2-year (45% versus 58%; P<0.001) survival compared with patients without RHF. RHF risk ranged from 11% (low risk score 0-2) to 43.1% (high risk score >4; P<0.0001). Median intensive care unit stay was 7 days (interquartile range, 4-15 days) versus 24 days (interquartile range, 14-38 days) in patients without versus with RHF, respectively (P<0.001). The c index of the composite score was 0.70 in the derivation and 0.67 in the validation cohort. The EUROMACS-RHF risk score outperformed (P<0.0001) previously published scores and known individual echocardiographic and hemodynamic markers of RHF. CONCLUSIONS: This novel EUROMACS-RHF risk score outperformed currently known risk scores and clinical predictors of early postoperative RHF. This novel score may be useful for tailored risk-based clinical assessment and management of patients with advanced HF evaluated for ventricular assist device therapy.

Cite

CITATION STYLE

APA

Soliman, O. I. I., Akin, S., Muslem, R., Boersma, E., Manintveld, O. C., Krabatsch, T., … Caliskan, K. (2018). Derivation and validation of a novel right-sided heart failure model after implantation of continuous flow left ventricular assist devices. Circulation, 137(9), 891–906. https://doi.org/10.1161/CIRCULATIONAHA.117.030543

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free