Association between plasma lipoprotein(a) concentration and restenosis after stent implantation

17Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Background: The plasma concentration of lipoprotein (a) [Lp(a)] is associated with atherosclerotic and thrombotic vascular diseases. The aim of the present study was to evaluate the association between plasma Lp(a) concentration and in-stent restenosis. Methods and Results: One hundred and 9 patients with successful elective coronary stent implantation underwent follow-up angiography at 24±6 weeks. Restenosis after stent implantation occurred in 38 patients. Univariate analysis showed that the reference diameter of the lesion was smaller in the restenosis group (2.93±0.29 mm) than in the no-restenosis group (3.21±0.43mm) (p<0.05). The lesion was longer in the restenosis group (14.2± 5.3 mm) than in the no-restenosis group (11.6±4.9 mm) (p<0.05). Plasma Lp(a) concentrations in the restenosis group (30.5±23.9 mg/dl) were higher than in the no-restenosis group (16.9±11.1 mg/dl) (p<0.01). Other lipid concentrations were similar in both groups. Among the plasma Lp(a) concentrations, the rate of restenosis (71.4%) in the high Lp(a) group (>40 mg/dl) (n=14) was greater compared with the other groups: 33.3% in the intermediate Lp(a) group (10-40 mg/dl) (n=54), and 24.4% in the low Lp(a) group (<10mg/dl) (n=41) (p<0.01). The late loss (0.57±0.53 mm) in the low Lp(a) group was significantly less than the other groups: 0.88±0.47 mm in the intermediate Lp(a) group, and 1.08±0.56 mm in the high Lp(a) group (p<0.05). In a multivariate regression model, plasma Lp(a) concentration remained significant as an independent predictor of restenosis in patients undergoing stent implantation (p=0.020 odds ratio (OR) 1.37 95% conficence interval (CI) 1.050-1.793), although the reference diameter (p=0.025 OR 0.23 95% CI 0.061-0.830) and lesion length (p=0.021 OR 1.12 95%CI 1.017-1.232) were related to stent restenosis. Conclusions: Plasma Lp(a) concentration is an independent predictor of stent restenosis.

Cite

CITATION STYLE

APA

Kamitani, T., Taniguchi, T., Miyai, N., Kawasaki, T., Kawasaki, S., & Sugihara, H. (2005). Association between plasma lipoprotein(a) concentration and restenosis after stent implantation. Circulation Journal, 69(6), 644–649. https://doi.org/10.1253/circj.69.644

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free