Experimental demonstration of real-time cardiac physiology-based radiotherapy gating for improved cardiac radioablation on an MR-linac

4Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Cardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular tachycardia (VT) by delivering a single high-dose fraction to the VT isthmus. Cardiorespiratory motion induces position uncertainties resulting in decreased dose conformality. Electocardiograms (ECG) are typically used during cardiac MRI (CMR) to acquire images in a predefined cardiac phase, thus mitigating cardiac motion during image acquisition. Purpose: We demonstrate real-time cardiac physiology-based radiotherapy beam gating within a preset cardiac phase on an MR-linac. Methods: MR images were acquired in healthy volunteers (n = 5, mean age = 29.6 years, mean heart-rate (HR) = 56.2 bpm) on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) after obtaining written informed consent. The images were acquired using a single-slice balance steady-state free precession (bSSFP) sequence in the coronal or sagittal plane (TR/TE = 3/1.48 ms, flip angle = 48 (Formula presented.), SENSE = 1.5, (Formula presented.) (Formula presented.), voxel size = (Formula presented.) (Formula presented.), partial Fourier factor = 0.65, frame rate = 13.3 Hz). In parallel, a 4-lead ECG-signal was acquired using MR-compatible equipment. The feasibility of ECG-based beam gating was demonstrated with a prototype gating workflow using a Quasar MRI4D motion phantom (IBA Quasar, London, ON, Canada), which was deployed in the bore of the MR-linac. Two volunteer-derived combined ECG-motion traces (n = 2, mean age = 26 years, mean HR = 57.4 bpm, peak-to-peak amplitude = 14.7 mm) were programmed into the phantom to mimic dose delivery on a cardiac target in breath-hold. Clinical ECG-equipment was connected to the phantom for ECG-voltage-streaming in real-time using research software. Treatment beam gating was performed in the quiescent phase (end-diastole). System latencies were compensated by delay time correction. A previously developed MRI-based gating workflow was used as a benchmark in this study. A 15-beam intensity-modulated radiotherapy (IMRT) plan ((Formula presented.) Gy) was delivered for different motion scenarios onto radiochromic films. Next, cardiac motion was then estimated at the basal anterolateral myocardial wall via normalized cross-correlation-based template matching. The estimated motion signal was temporally aligned with the ECG-signal, which were then used for position- and ECG-based gating simulations in the cranial–caudal (CC), anterior–posterior (AP), and right–left (RL) directions. The effect of gating was investigated by analyzing the differences in residual motion at 30, 50, and 70% treatment beam duty cycles. Results: ECG-based (MRI-based) beam gating was performed with effective duty cycles of 60.5% (68.8%) and 47.7% (50.4%) with residual motion reductions of 62.5% (44.7%) and 43.9% (59.3%). Local gamma analyses (1%/1 mm) returned pass rates of 97.6% (94.1%) and 90.5% (98.3%) for gated scenarios, which exceed the pass rates of 70.3% and 82.0% for nongated scenarios, respectively. In average, the gating simulations returned maximum residual motion reductions of 88%, 74%, and 81% at 30%, 50%, and 70% duty cycles, respectively, in favor of MRI-based gating. Conclusions: Real-time ECG-based beam gating is a feasible alternative to MRI-based gating, resulting in improved dose delivery in terms of high (Formula presented.) rates, decreased dose deposition outside the PTV and residual motion reduction, while by-passing cardiac MRI challenges.

Author supplied keywords

References Powered by Scopus

A Real-Time QRS Detection Algorithm

6401Citations
N/AReaders
Get full text

Risk of ischemic heart disease in women after radiotherapy for breast cancer

3083Citations
N/AReaders
Get full text

Principles and applications of balanced SSFP techniques

587Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Feasibility of volumetric-modulated arc therapy gating for cardiac radioablation using real-time ECG signal acquisition and a dynamic phantom

0Citations
N/AReaders
Get full text

Electrocardiogram-gated cardiac computed tomography-based patient- and segment-specific cardiac motion estimation method in stereotactic arrhythmia radioablation for ventricular tachycardia

0Citations
N/AReaders
Get full text

Evaluation of the impact of cardiac implantable electronic devices on cine MRI for real-time adaptive cardiac radioablation on a 1.5 T MR-linac

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Akdag, O., Borman, P. T. S., Mandija, S., Woodhead, P. L., Uijtewaal, P., Raaymakers, B. W., & Fast, M. F. (2024). Experimental demonstration of real-time cardiac physiology-based radiotherapy gating for improved cardiac radioablation on an MR-linac. Medical Physics, 51(4), 2354–2366. https://doi.org/10.1002/mp.17024

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

50%

Professor / Associate Prof. 2

33%

Researcher 1

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

40%

Physics and Astronomy 1

20%

Social Sciences 1

20%

Pharmacology, Toxicology and Pharmaceut... 1

20%

Save time finding and organizing research with Mendeley

Sign up for free