A validated stability indicating HPLC method for the determination of process-related impurities in pantoprazole bulk drug and formulations

9Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

A stability-indicating high-performance liquid chromatographic (HPLC) method was developed with short run time and validated for the assay of process related impurities of pantoprazole in bulk form. Resolution of drug, its potential impurities and degradation products were achieved on a Hypersil ODS column utilizing a gradient with 0.01 M phosphate buffer of pH 7 and acetonitrile as eluent, at the detection wavelength of 290 nm. Flow rate was set at 1 mL min-1. The procedure was found to be specific, linear (r=0.999), recovery (97.9-103%), LOD (0.043-0.047 μgmL-1), LOQ (0.13-0.14 μgmL-1) and robust. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations. Pantoprazole was found to degrade in acidic, oxidative and under photolytic stress conditions. The drug was stable to alkaline and dry heat conditions. This method has been successively applied to pharmaceutical formulation and no interference from the excipients was found.

Cite

CITATION STYLE

APA

Pandey, S., Pandey, P., Mishra, D., & Singh, U. K. (2013). A validated stability indicating HPLC method for the determination of process-related impurities in pantoprazole bulk drug and formulations. Brazilian Journal of Pharmaceutical Sciences, 49(1), 175–184. https://doi.org/10.1590/S1984-82502013000100019

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free