Influence of stent flexibility on artery wall stress and wall shear stress in bifurcation lesions

6Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Stent flexibility can influence clinical outcome, especially in bifurcation lesions. For instance, an overly rigid stent can impose mechanical stress on the artery at the stent edges and alter both arterial geometry and blood flow dynamics in bifurcations. This study investigated the influence of stent flexibility on vessel geometry, histology, wall stress, and blood flow dynamics in arterial bifurcations. Materials and Methods: We compared arterial angulation, stenosis, histopathology, simulated wall shear stress (WSS), and simulated blood flow velocity distribution in swine coronary artery bifurcations following placement of the less flexible Multi-link 8 or more flexible Kaname stent (4.1 ± 0.5 vs 1.5 ± 0.1 mN, p < 0.05, t-test). Stents were implanted into six coronary artery bifurcations each using the single-stent crossover technique without side branch strut dilatation. Outcomes were examined after 28 days. Results: Implantation of both stents significantly increased site angulation (Multi-link 8: 148° ± 8° to 172° ± 2°, p < 0.05, paired t-test; Kaname: 152° ± 5° to 164° ± 4°, p < 0.05, paired t-test), but the change tended to be greater after Multi-link 8 stent implantation (24° ± 15° vs 11° ± 7°, p = 0.1, t-test), suggesting greater straightening of the bifurcation. The Multi-link 8 stent induced greater neointimal thickness than the Kaname stent (0.53 ± 0.3 mm vs 0.26 ± 0.1 mm, p < 0.05, t-test). The distribution of neointimal hyperplasia following stent implantation as revealed by longitudinal histopathology matched the distribution of WSS simulated using computational fluid dynamics (CFD). The endothelium at low WSS areas exhibited aberrant cell morphology and leukocyte adhesion. A CFD model of a curved bifurcation suggested that the region of low WSS is expanded by artery straightening. Conclusion: In bifurcated lesions, stent flexibility influences not only mechanical stress on the artery but also WSS, which may induce local neointimal hyperplasia.

References Powered by Scopus

Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trial

692Citations
N/AReaders
Get full text

Pulsatile flow in the human left coronary artery bifurcation: Average conditions

613Citations
N/AReaders
Get full text

Everolimus-eluting bioresorbable scaffolds for coronary artery disease

585Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A 3D Bioprinted In Vitro Model of Pulmonary Artery Atresia to Evaluate Endothelial Cell Response to Microenvironment

18Citations
N/AReaders
Get full text

The road to the ideal stent: A review of stent design optimisation methods, findings, and opportunities

15Citations
N/AReaders
Get full text

Design and Shape Optimization of a Biodegradable Polymeric Stent for Curved Arteries Using FEM

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Saito, N., Mori, Y., & Komatsu, T. (2020). Influence of stent flexibility on artery wall stress and wall shear stress in bifurcation lesions. Medical Devices: Evidence and Research, 13, 365–375. https://doi.org/10.2147/MDER.S275883

Readers' Seniority

Tooltip

Researcher 2

67%

PhD / Post grad / Masters / Doc 1

33%

Readers' Discipline

Tooltip

Engineering 3

60%

Medicine and Dentistry 1

20%

Biochemistry, Genetics and Molecular Bi... 1

20%

Save time finding and organizing research with Mendeley

Sign up for free