The correct volume of sample and time of storing prior to the analysis are important considerations in the estimation of plasma glucose concentration of patients. The present study was to determine the effect of sample volume variation and time delay in the analysis of plasma glucose results in healthy adults. A total of 30 individuals aged between 20 and 30 years were selected for the study. Blood samples were collected into three fluoride-oxalate collection tubes separately. The results revealed that the sample volume variation from 2.0 mL fluoride-oxalate tube to 1.0 mL and 3.0 mL did not significantly affect the plasma glucose concentration (p > 0.05). However, the plasma glucose concentration in the sample significantly decreased upon delaying the analysis. The mean fasting plasma glucose concentration of analysis after one hour of collection and analysis after three hours of collection was not significantly different (p > 0.05). The mean fasting plasma glucose concentrations between one hour and five hours timepoints after collection (p < 0.001) and between three hours and five hours after collection (p = 0.014) were significantly different. In conclusion, overfilling and underfilling (2.0 ± 1.0 mL) of fluoride-oxalate tubes did not affect the plasma glucose results significantly. If the samples are analyzed within three hours of collection, the time dependent change too is not statistically significant.
CITATION STYLE
Dharmasena, I. A., Siriwardhana, D., & Attanayake, A. P. (2021). Effect of Sample Volume Variation and Delay in Analysis on Plasma Glucose Concentration in Sri Lankan Healthy Adults. Scientifica, 2021. https://doi.org/10.1155/2021/6061206