Basal-prandial insulin delivery in type 2 diabetes mellitus via the V-Go™: A novel continuous subcutaneous infusion device

21Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The V-Go™ is a once-daily disposable device that allows coverage of basal and prandial insulin requirements over a period of 24 hours. The aim of this proof-of-concept study was to evaluate the clinical functionality, safety, and pharmacodynamics of the V-Go delivering insulin aspart and redistributing a single basal dose of insulin glargine as a constant basal infusion supplemented with prandial insulin in subjects with type 2 diabetes mellitus. Methods: In six subjects receiving once-daily subcutaneous (SC) injections of insulin glargine (≥15 U/day) with or without concomitant oral antidiabetic drugs, glargine was discontinued following a 3-day baseline phase. The V-Go was then applied to the lower abdomen of the subjects once daily for 7 days (days 1-3 inpatient, days 4-7 outpatient). Each V-Go provided a continuous 24-hour preset basal infusion rate of insulin aspart (0.6 U/h) and up to three daily prandial doses at mealtimes. Capillary blood glucose concentrations were measured at 11 time points per day during the baseline and inpatient phases and at 4 time points per day during the outpatient phase. Additionally, glucose profiles were measured continuously on all days. Results: The V-Go was well tolerated and operated as anticipated. The mean ± SEM prestudy daily dose of SC insulin glargine was 33.3 ± 13.8 U; the mean daily total insulin aspart dose infused with the V-Go was 31.5 ± 7.5 and 32.3 ± 7.8 U for the inpatient and outpatient periods, respectively. Fasting blood glucose values were similar to those observed at baseline throughout the study, with nonsignificant (NS) reductions in readings collected during the outpatient phase before lunch (-35 ± 27 mg/dl) and before dinner (-38 ± 25 mg/dl). The 2-hour postprandial glucose trended lower from 231 to 195 mg/dl (NS) at breakfast, 234 to 166 mg/dl (NS) at lunch, and 222 to 171 mg/dl (NS) at dinner. Bedtime blood glucose decreased (mean change from baseline-52 ± 21 mg/dl; P = 0.0313), as did nighttime (3:00 AM) measurements (-20 ± 9 mg/dl; P = 0.0313). Overall glycemic control tended to improve, as shown by continuous glucose monitoring changing from 173 to 157 mg/dl (P = 0.063, NS) and 156 mg/dl (P = 0.219) during inpatient and outpatient periods, respectively. Glycemic variability assessed by the M value similarly tended to decrease from 33 ± 9 to 25 ± 4 (NS) and 21 ± 4 (NS) for inpatient and outpatient periods, respectively. © Diabetes Technology Society.

Cite

CITATION STYLE

APA

Kapitza, C., Fein, S., Heinemann, L., Schleusener, D., Levesque, S., & Strange, P. (2008). Basal-prandial insulin delivery in type 2 diabetes mellitus via the V-GoTM: A novel continuous subcutaneous infusion device. Journal of Diabetes Science and Technology, 2(1), 40–46. https://doi.org/10.1177/193229680800200107

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free