An electrochemical biosensor for acrylamide determination: Merits and limitations

22Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

The present work reports the results concerning the development and implementation of the first electrochemical biosensor for acrylamide determination, based on a direct biochemical interaction between the analyte and intact bacterial cells, with intracellular enzymatic activity. The biological recognition element consisted of whole cells of Pseudomonas aeruginosa containing intracellular amidase activity, which catalyses the hydrolysis of acrylamide producing ammonium ion (NH 4+) and acrylic acid. The transduction process was accomplished by means of an ammonium ion selective electrode. Whole cells were firstly immobilized on single discs of polymeric membranes, such as polyethersulphone, nylon and polycarbonate, which were, then, attached to the surface of the selective electrode. However, it was observed a significant loss of cells each time the biosensor was used, namely at the beginning of the assay, when the membranes were attached to the ammonium electrode, and after the assay, when removed for storage purposes. This evidence determined a premature decrease in the biosensor's stability. Instead of using single membrane discs, a "sandwich" design, with two membrane discs was considered. This way the cells remain contained between the membranes, never contacting the electrode's surface, preventing their premature loss. Consequently, the activity of the biosensor could be maintained for longer periods of time. The analytical performance of the biosensor was evaluated. The best results were obtained when polyethersulphone double membranes were used. A typical response of 120 mV (after 6 min reaction time), a Nernstian slope of 48 mV/decade, a limit of detection of 6.31×10 -4 M and a half-life time of 27 days, are examples of some figures of merit observed for this biosensor.

References Powered by Scopus

Electrochemical biosensors - Sensor principles and architectures

2005Citations
N/AReaders
Get full text

Chemistry, biochemistry, and safety of acrylamide. A review

1128Citations
N/AReaders
Get full text

Electrochemical sensors for environmental monitoring: Design, development and applications

317Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Rapid methods for detecting acrylamide in thermally processed foods: A review

72Citations
N/AReaders
Get full text

Nanosensors for the Detection of Food Contaminants

67Citations
N/AReaders
Get full text

Preparation, characterization and application of haemoglobin nanoparticles for detection of acrylamide in processed foods

41Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Silva, N. A. F., Matos, M. J., Karmali, A., & Rocha, M. M. (2011). An electrochemical biosensor for acrylamide determination: Merits and limitations. Portugaliae Electrochimica Acta, 29(5), 361–373. https://doi.org/10.4152/pea.201105361

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 11

61%

Professor / Associate Prof. 6

33%

Researcher 1

6%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 8

44%

Chemistry 6

33%

Chemical Engineering 2

11%

Biochemistry, Genetics and Molecular Bi... 2

11%

Save time finding and organizing research with Mendeley

Sign up for free