Evaluation of anti-dsDNA antibody tests: Crithidia luciliae immunofluorescence test, immunoblot, enzyme-linked immunosorbent assay, chemiluminescence immunoassay

7Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

Background : Anti-double stranded DNA antibody (anti-dsDNA) test is useful for the diagnosis and monitoring of systemic lupus erythematosus (SLE). Although several methods are available, none of them is completely satisfactory and differences among them have been reported. We evaluated the diagnostic performance of 6 commercial kits for anti-dsDNA detection. Methods : A total of 142 sera (SLE [N=74], other systemic rheumatic diseases [N=50], other diseases [N=18]) were tested by 6 different assay kits using different antigenic sources of DNA: Crithidia luciliae immunofluorescence test (CLIFT), salmon testes (immunoblot, IB), human (ELISA I), salmon testes with nucleosome linker (ELISA II), plasmid (ELISA III), and synthetic oligonucleotides (chemiluminescence immunoassay, CLIA). Results : With manufacturers' cut-off values, 6 test kits showed sensitivities of 55.4-91.9%. ELISA I had a greater sensitivity than the other five assays (P<0.001). The specificities of ELISA II, ELISA III, CLIA, and CLIFT were higher than those of ELISA I and IB (P<0.05). In ROC curve analysis, 3 ELISA kits and CLIA showed AUC values of 0.845-0.893, and revealed no significant differences among them (P>0.05). With cut-off values set at 95% of specificity, ELISA Il had a higher sensitivity than ELISA III (63.5% vs. 41.9%, P<0.05). IB had poor concordance rates with other assays (42.0-65.0%). Pearson correlation coefficients among 4 quantitative assays were 0.667-0.798. Conclusions : Six different assays showed various performances depending on the methods and cut-off values used. Except IB, the other five assays can be used for the detection of anti-dsDNA. ©The Korean Society for Laboratory Medicine.

Cite

CITATION STYLE

APA

Yang, J. Y., Oh, E. J., Kim, Y., & Park, Y. J. (2010). Evaluation of anti-dsDNA antibody tests: Crithidia luciliae immunofluorescence test, immunoblot, enzyme-linked immunosorbent assay, chemiluminescence immunoassay. Korean Journal of Laboratory Medicine, 30(6), 675–684. https://doi.org/10.3343/kjlm.2010.30.6.675

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free