Failure assessment of steel/CFRP double strap joints

23Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

In the current study, the failure behavior of retrofitted steel structures was studied experimentally and theoretically with steel/carbon fiber reinforced polymer (CFRP) double strap joints (DSJs) under quasi-static tensile loading. A series of DSJs with different bonding lengths are also considered and examined to experimentally assess the effective bond length. To predict the failure load values of the tested specimens, a new stress-based method, namely the point stress (PS) method is proposed. Although some theoretical predictive modelling for the strength between steel/CFRP joints under various loading conditions has been presented, in this work by using the new proposed approach, one can calculate rapidly and conveniently the failure loads of the steel/CFRP specimens. Furthermore, to assess the validity of the new proposed method, further experimental data on steel/CFRP DSJs available in the open literature are predicted using the PS method. Finally, it was found that a good agreement exists between the experimental results and the theoretical predictions based on the PS method.

Cite

CITATION STYLE

APA

Majidi, H. R., Razavi, S. M. J., & Berto, F. (2017). Failure assessment of steel/CFRP double strap joints. Metals, 7(7). https://doi.org/10.3390/met7070255