Background: Single bolus quantitative myocardial perfusion is sensitive to systematic errors due to the non-linear relationship between contrast agent concentration and MR signal. These errors can be minimised by using a low dose contrast bolus or by altering the imaging sequence parameters. However, these approaches substantially reduce the contrast to noise ratio of the images increasing the noise in the myocardial blood flow (MBF) values. This study compared two techniques proposed to address these issues; the dual-bolus technique and dual-sequence imaging. Methods: Seven patients undergoing outpatient investigation for suspected coronary artery disease underwent rest and adenosine induced stress dynamic contrast enhanced myocardial perfusion CMR. A pre-bolus of 0.005mmol/kg of Gadovist® was used followed by a main bolus of 0.05mmol/kg. Injection volumes and rates were matched. Imaging was performed using a saturation-recovery prepared turbo gradient echo (SRTGE) sequence to acquire three slices through the heart (144×144 acquisition matrix, FOV 360×360) with a pre-pulse delay (PPD) of 95.9ms. The Philips instantaneous scan-switching/interleaving capability was used to acquire an additional low resolution (64×64 acquisition matrix) image directly after the first-slice saturation pulse with a PPD of 24.3ms. Precontrast proton density weighted (PDW) images were acquired using the same pulse sequence with the saturation pulse turned off. Enhancement curves were converted to concentrations using the pulse sequence equation and parameters in addition to the pre-contrast signal and PDW values. Curves were selected for the two analyses as shown in the figure and the area under the curve (AUC) of each AIF was calculated. MBF values were generated using Fermi-constrained deconvolution. Results: The quantitative perfusion results are summarised in the table. Dual-bolus MBF values were significantly smaller than dual-sequence values (p<0.05) and gave a greater MPR (borderline significance p=0.06). The AUC of the dose corrected pre-bolus was significantly greater than that for the bolus (p<0.05). Conclusions: Both methods generated MBF estimates that are within literature ranges. However, the values between the two methods differed significantly. The AUC of the main bolus was lower than that of the dose corrected pre-bolus. This would be consistent with a reduced dose ratio, perhaps due to dilution of the main bolus in the line, or inaccuracies in the concentration conversion procedure, due to the limitations of the imaging sequence (e.g. an imperfect saturation and/or readout pulses). These results call into question the accuracy of these techniques and highlight the need for future studies to isolate the causes of these discrepancies. (Figure Presented).
CITATION STYLE
Biglands, J. D., Ripley, D. P., Broadbent, D. A., Higgins, D. M., Swoboda, P. P., McDiarmid, A. K., … Buckley, D. L. (2015). A comparison of dual-bolus and dual-sequence quantitative myocardial perfusion techniques. Journal of Cardiovascular Magnetic Resonance, 17, P50. https://doi.org/10.1186/1532-429x-17-s1-p50
Mendeley helps you to discover research relevant for your work.