PET image denoising using a synergistic multiresolution analysis of structural (MRI/CT) and functional datasets

43Citations
Citations of this article
55Readers
Mendeley users who have this article in their library.

Abstract

PET allows the imaging of functional properties of the living tissue, whereas other modalities (CT, MRI) provide structural information at significantly higher resolution and better image quality. Constraints for injected radioactivity, technologic limitations of current instrumentation, and inherent spatial uncertainties on the decaying process affect the quality of PET images. In this article we illustrate how structural information of matched anatomic images can be used in a multiresolution model to enhance the signal-to-noise ratio of PET images. The model states a flexible relation between function and structure in the brain and replaces high-resolution information of PET images with appropriately scaled MRI or CT local detail. The method can be naturally extended to other functional imaging modalities (SPECT, functional MRI). Methods: The methodology is based on the multiresolution property of the wavelet transform (WT). First, the coregistered structural image (MRI/CT) is down-graded to the resolution of the PET volume through appropriate filtering. Second, a redundant version of the WT is applied to both volumes. Third, a linear model is applied to the set of local coefficients of both image volumes and resulting parameters are recorded. The overall set of linear coefficients is then modeled as a mixture of multivariate gaussian distributions and fitted through a k-means algorithm. Finally, the local wavelet coefficients of the PET image are substituted by the corresponding valuesof the MRI/CT set calibrated according to the resulting clustering. The methodology was validated on digital simulated images and clinical data to evaluate its quantitative potential for individual as well as group analysis. Results: Application to real and simulated datasets shows very effective noise reduction (15% SD) while resolution is preserved. Conclusion: Themethodology is robust to errors in the coregistration parameters, practical to implement, and computationally fast. COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.

Cite

CITATION STYLE

APA

Turkheimer, F. E., Boussion, N., Anderson, A. N., Pavese, N., Piccini, P., & Visvikis, D. (2008). PET image denoising using a synergistic multiresolution analysis of structural (MRI/CT) and functional datasets. Journal of Nuclear Medicine, 49(4), 657–666. https://doi.org/10.2967/jnumed.107.041871

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free