Autologous platelet gel: An in vitro analysis of platelet-rich plasma using multiple cycles

13Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Autologous platelet gel (APG) has become an expanding field for perfusionists. By mixing platelet-rich plasma (PRP) with thrombin and calcium, platelet gel is prepared and used in many surgical settings. There are many devices used to produce PRP. This study evaluates the Medtronic Magellan Autologous Platelet Separator. The purpose of this study was to show that processing two cycles of the same syringe could reduce the amount of blood required to produce a specific volume of PRP. Three 60-mL syringes of whole blood with anticoagulant were removed from 15 elective coronary artery bypass patients. Each syringe produced 9 mL of PRP and 1 mL was sent to the laboratory for analysis. The remaining whole blood in each syringe was processed a second time with a yield of 5 mL of PRP with 1 mL sent to the laboratory. With this data, the Magellan was assessed in three phases. The first phase focused on the consistency of the Magellan. Laboratory values of hematocrit, platelet count, white blood cell count, and fibrinogen were compared between each syringe processed by the device. The second phase dealt with the percentage of platelets in the PRP that the Magellan was able to capture. Finally, results of both cycles were combined and compared against baseline values. Most of the hematological factors evaluated between each syringe were consistent in both cycles. The Magellan was able to capture nearly 70% of all platelets in the PRP of the first cycle and 18.5% in the second cycle. By mathematically combining both cycles, platelet counts averaged 2.8 times baseline with a 3.3 times baseline increase when the volume of the two cycles was weighted. This weighted average was done to reflect a higher concentration of Cycle 1 platelets than Cycle 2 in each sample. This study proved that processing each syringe of whole blood twice could reduce blood requirements while maintaining an effective platelet yield and volume. It also showed that the Magellan does conform to benchmark testing done at Medtronic.

References Powered by Scopus

Autologous platelets as a source of proteins for healing and tissue regeneration

1138Citations
N/AReaders
Get full text

Platelet gel for healing cutaneous chronic wounds

357Citations
N/AReaders
Get full text

Current applications of platelet gels in facial plastic surgery

277Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Classification of platelet concentrates: from pure platelet-rich plasma (P-PRP) to leucocyte- and platelet-rich fibrin (L-PRF)

1377Citations
N/AReaders
Get full text

Platelet-rich plasma: The PAW classification system

446Citations
N/AReaders
Get full text

Bacterial biofilm formation and treatment in soft tissue fillers

56Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Christensen, K., Vang, S., Brady, C., Isler, J., Allen, K., Anderson, J., & Holt, D. (2006). Autologous platelet gel: An in vitro analysis of platelet-rich plasma using multiple cycles. Journal of Extra-Corporeal Technology, 38(3), 249–253. https://doi.org/10.1051/ject/200638249

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

50%

Researcher 4

40%

Lecturer / Post doc 1

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 8

67%

Biochemistry, Genetics and Molecular Bi... 2

17%

Social Sciences 1

8%

Neuroscience 1

8%

Save time finding and organizing research with Mendeley

Sign up for free