The GEM-handle as convenient labeling strategy for bimodal single-domain antibody-based tracers carrying 99mTc and a near-infrared fluorescent dye for intra-operative decision-making

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Intra-operative fluorescence imaging has demonstrated its ability to improve tumor lesion identification. However, the limited tissue penetration of the fluorescent signals hinders the detection of deep-lying or occult lesions. Integrating fluorescence imaging with SPECT and/or intra-operative gamma-probing synergistically combines the deep tissue penetration of gamma rays for tumor localization with the precision of fluorescence imaging for precise tumor resection. In this study, we detail the use of a genetically encoded multifunctional handle, henceforth referred to as a GEM-handle, for the development of fluorescent/radioactive bimodal single-domain antibody (sdAb)-based tracers. A sdAb that targets the urokinase plasminogen activator receptor (uPAR) was engineered to carry a GEM-handle containing a carboxy-terminal hexahistidine-tag and cysteine-tag. A two-step labeling strategy was optimized and applied to site-specifically label IRDye800CW and 99mTc to the sdAb. Bimodal labeling of the sdAbs proved straightforward and successful. 99mTc activity was however restricted to 18.5 MBq per nmol fluorescently-labeled sdAb to prevent radiobleaching of IRDye800CW without impeding SPECT/CT imaging. Subsequently, the in vivo biodistribution and tumor-targeting capacity of the bimodal tracer were evaluated in uPAR-positive tumor-bearing mice using SPECT/CT and fluorescence imaging. The bimodal sdAb showed expected renal background signals due to tracer clearance, along with slightly elevated non-specific liver signals. Four hours post-injection, both SPECT/CT and fluorescent images achieved satisfactory tumor uptake and contrast, with significantly higher values observed for the anti-uPAR bimodal sdAb compared to a control non-targeting sdAb. In conclusion, the GEM-handle is a convenient method for designing and producing bimodal sdAb-based tracers with adequate in vivo characteristics.

References Powered by Scopus

Shedding light onto live molecular targets

1802Citations
N/AReaders
Get full text

Image-guided cancer surgery using near-infrared fluorescence

1186Citations
N/AReaders
Get full text

Latest developments in molecular tracers for fluorescence image-guided cancer surgery

346Citations
N/AReaders
Get full text

Cited by Powered by Scopus

<sup>99m</sup>Tc(I)-Labeled His-Tagged Proteins: Impact in the Development of Novel Imaging Probes and in Drug Discovery

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Declerck, N. B., Huygen, C., Mateusiak, L., Stroet, M. C. M., & Hernot, S. (2023). The GEM-handle as convenient labeling strategy for bimodal single-domain antibody-based tracers carrying 99mTc and a near-infrared fluorescent dye for intra-operative decision-making. Frontiers in Immunology, 14. https://doi.org/10.3389/fimmu.2023.1285923

Readers over time

‘23‘2400.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Professor / Associate Prof. 1

33%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 1

33%

Medicine and Dentistry 1

33%

Biochemistry, Genetics and Molecular Bi... 1

33%

Save time finding and organizing research with Mendeley

Sign up for free
0