Abstract

Objectives: Accurate pre-operative imaging of parathyroid adenomas (PAs) is essential for successfulminimally invasive surgery; however, rates of non-localizing PAs can be as high as 18%. Multiphasic dual-energy CT (DECT) has the potential to increase accuracy of PA detection by enabling creation of pairedmaterialmaps and spectral tissue characterization. This study prospectively evaluated the utility of 3-phase DECT for PA identification in patients with failed localizatio n via standard imaging. Methods: Patientswith primary hyperparathyroidism and non-localizing PAs underwent a 3 phase post-contrast DECT scan acquired at 25, 55, and 85 s. The scans were prospectively evaluated by two head and neck radiologists. Pre-operative localization was compared to intraoperative localization and final histopathology. A post-hoc DECT spectral density characterization was performed on pathologically-proven PAs. Results: Out of 29 patients with primary hyperparathyroidism and non-localized PAs, DECT identified candidates in 26. Of the 23 patients who underwent parathyroidectomy, DECT provided precise anatomic localization in 20 patients (PPV = 87.0 %), one with multi-gland disease. The virtual unenhanced images were not found to be useful for diagnosis but successful diagnosis was made without an unenhanced phase regardless. Spectral analysis demonstrated a distinct spectral Hounsfield attenuation curve for PAs compared to lymph nodes on arterial phase images. Conclusion: 3-phase DECT without an unenhanced phase is a feasible salvage imaging modality for previously nonlocalizing parathyroid adenomas. Optimal interpretation is achieved based on a combination of perfusion characteristics and other morphologic features. Advanced spectral DECT analysis has the potential for further increasing accuracy of PA identification in the future.

Cite

CITATION STYLE

APA

Roskies, M., Liu, X., Hier, M. P., Payne, R. J., Mlynarek, A., Forest, V., … Forghani, R. (2015). 3-phase dual-energy CT scan as a feasible salvage imaging modality for the identification of non-localizing parathyroid adenomas: A prospective study. Journal of Otolaryngology - Head and Neck Surgery, 44(1). https://doi.org/10.1186/s40463-015-0098-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free