Depth of cure and hardness of an indirect composite polymerized with three laboratory curing units.

6Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

This study determined the hardness and curing depth of a light-activated indirect composite polymerized with three laboratory light-polymerizing units for the purpose of comparing the curing performance of the three units. A light-activated composite material for indirect application (Vita Zeta) was polymerized with three light-polymerizing units equipped with the following light sources: 1) one halogen lamp and two fluorescent lamps (alpha-Light II); 2) three halogen lamps (Twinkle HLG); and 3) one metal halide lamp (Twinkle LI). Knoop hardness and curing depth were determined for groups of five specimens using standardized testing methods. The results were compared using analysis of variance (ANOVA) and Scheffé's S intervals (alpha = 0.05). The Knoop hardness number (KHN) generated with the halogen-fluorescent unit (12.5 KHN) was significantly (P < 0.05) lower than those produced by the halogen unit (13.9 KHN) and the metal halide unit (14.2 KHN). Of the three units, the halogen-fluorescent unit exhibited the lowest depth of cure. Both the hardness and curing depth of the composite were influenced by the laboratory polymerizing units employed.

Cite

CITATION STYLE

APA

Tanoue, N., Murakami, M., Koizumi, H., Atsuta, M., & Matsumura, H. (2007). Depth of cure and hardness of an indirect composite polymerized with three laboratory curing units. Journal of Oral Science, 49(1), 25–29. https://doi.org/10.2334/josnusd.49.25

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free