Sensitivity of five rapid HIV tests on oral fluid or Finger-Stick whole blood: A real-time comparison in a healthcare setting

128Citations
Citations of this article
148Readers
Mendeley users who have this article in their library.

Abstract

Background: Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known. Methods and Findings: 200 adults with documented HIV-1 (n = 194) or HIV-2 infection (n = 6) were prospectively screened with five HIV rapid tests using either oral fluid (OF) or finger-stick whole blood (FSB). The OraQuick Advance rapid HIV1/2® was first applied to OF and then to FSB, while the other tests were applied to FSB, in the following order: Vikia HIV 1/2®, Determine HIV 1-2®, Determine® HIV-1/2 Ag/Ab Combo® and INSTI HIV-1/HIV-2®. Tests negative on FSB were repeated on paired serum samples. Twenty randomly selected HIV-seronegative subjects served as controls, and the results were read blindly. Most patients had HIV-1 subtype B infection (63.3%) and most were on antiretroviral therapy (68.5%). Sensitivity was 86.5%, 94.5%, 98.5%, 94.9%, 95.8% and 99% respectively, with OraQuick OF, OraQuick FSB, Vikia, Determine, Determine Ag/Ab Combo and INSTI (p<0.0001). OraQuick was less sensitive on OF than on FSB (p = 0.008). Among the six patients with three or more negative tests, two had recent HIV infection and four patients on antiretroviral therapy had undetectable plasma viral load. When patients positive in all the tests were compared with patients who had at least one negative test, only a plasma HIV RNA level <200 cp/ml was significantly associated with a false-negative result (p = 0.009). When the 33 rapid tests negative on FSB were repeated on serum, all but six (5 negative with OraQuick, 1 with INSTI) were positive. The sensitivity of OraQuick, Determine and Determine Ag/Ab Combo was significantly better on serum than on FSB (97.5%, p = 0.04; 100%, p = 0.004; and 100%, p = 0.02, respectively). Conclusion: When evaluated in a healthcare setting, rapid HIV tests were less sensitive on oral fluid than on finger-stick whole blood and less sensitive on finger-stick whole blood than on serum. © 2010 Pavie et al.

Figures

  • Table 1. Technical characteristic of EU-approved HIV screening rapid tests for use on whole blood and/or oral fluid.
  • Table 2. Sensitivity of five rapid HIV tests in 200 HIV-infected patients, using either oral fluid (OF) or finger-stick whole blood (FSB).
  • Table 3. Sensitivity of five rapid HIV tests in 200 HIV-infected patients, combining the results for finger-stick whole blood and, when the latter was negative, for serum.
  • Table 4. Comparison of patient characteristics according to HIV screening rapid tests results on whole blood and/or oral fluid results.
  • Table 5. Sensitivity of rapid test detection according to the HIV genotype.

References Powered by Scopus

Dynamics of HIV viremia and antibody seroconversion in plasma donors: Implications for diagnosis and staging of primary HIV infection

1079Citations
N/AReaders
Get full text

Mortality of HIV-1-infected patients in the first year of antiretroviral therapy: Comparison between low-income and high-income countries

975Citations
N/AReaders
Get full text

Racial and sex disparities in life expectancy losses among hiv-infected persons in the united states: Impact of risk behavior, late initiation, and early discontinuation of antiretroviral therapy

171Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Antiretroviral prophylaxis for HIV infection in injecting drug users in Bangkok, Thailand (the Bangkok Tenofovir Study): A randomised, double-blind, placebo-controlled phase 3 trial

1171Citations
N/AReaders
Get full text

Microfluidics-based diagnostics of infectious diseases in the developing world

661Citations
N/AReaders
Get full text

Evaluation of a newly developed lateral flow immunoassay for the diagnosis of cryptococcosis

194Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Pavie, J., Rachline, A., Loze, B., Niedbalski, L., Delaugerre, C., Laforgerie, E., … Simon, F. (2010). Sensitivity of five rapid HIV tests on oral fluid or Finger-Stick whole blood: A real-time comparison in a healthcare setting. PLoS ONE, 5(7). https://doi.org/10.1371/journal.pone.0011581

Readers over time

‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2506121824

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 63

58%

Researcher 31

29%

Professor / Associate Prof. 12

11%

Lecturer / Post doc 2

2%

Readers' Discipline

Tooltip

Medicine and Dentistry 45

52%

Agricultural and Biological Sciences 17

20%

Immunology and Microbiology 13

15%

Engineering 11

13%

Save time finding and organizing research with Mendeley

Sign up for free
0