Purification of Biodiesel via Nanofluid using Liquid-Liquid Extraction in a Membrane Contactor

4Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Recently, attention has been paid to nanofluids due to their contribution to enhancing heat and mass transfer in different industrial applications. Consequently, a nanofluid composed of SiO2 nanoparticles (NPs) and distilled water as base fluid was adopted as a solvent to promote the removal of impurities, methanol, and glycerol, from crude biodiesel using liquid-liquid extraction in the membrane contactor. The presence of NPs significantly enhanced the methanol and glycerol removal efficiency. The optimum concentration of NPs in nanofluid was 0.01 wt%. It was found that adding 0.01 wt% of NPs to the distilled water increased the methanol removal efficiency from 76.4% to 93.1% upon using crude biodiesel with methanol and glycerol content of 2000 ppm and 1 wt%, respectively, at a constant flow rate of solvent and biodiesel of 200 mL min⎼1. Meanwhile, the glycerol removal efficiency increased from 76.2% to 94.5%. The results revealed that the solvent flow rate was the controlling mass transfer step.

Cite

CITATION STYLE

APA

Ahmed, S. H., Mohammed, H. N., & Abdulkarim, A. A. (2023). Purification of Biodiesel via Nanofluid using Liquid-Liquid Extraction in a Membrane Contactor. Tikrit Journal of Engineering Sciences, 30(1), 54–65. https://doi.org/10.25130/tjes.30.1.5