A line-scanning semi-confocal multi-photon fluorescence microscope with a simultaneous broadband spectral acquisition and its application to the study of the thylakoid membrane of a cyanobacterium Anabaena PCC7120

29Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We describe the construction and characterization of a laser-line-scanning microscope capable of detection of broad fluorescence spectra with a resolution of 1 nm. A near-infrared femtosecond pulse train at 800 nm was illuminated on a line (one lateral axis, denoted as X axis) in a specimen by a resonant scanning mirror oscillating at 7.9 kHz, and total multi-photon-induced fluorescence from the linear region was focused on the slit of an imaging polychromator. An electron-multiplying CCD camera was used to resolve fluorescence of different colours at different horizontal pixels and fluorescence of different spatial positions in a specimen at different vertical pixels. Scanning on the other two axes (Y and Z) was achieved by a closed-loop controlled sample scanning stage and a piezo-driven objective actuator. The full widths at half maximum of the point-spread function of the system were estimated to be 0.39-0.40, 0.33 and 0.56-0.59 μm for the X (lateral axis along the line-scan), Y (the other lateral axis) and Z axes (the axial direction), respectively, at fluorescence wavelengths between 644 and 690 nm. A biological application of this microscope was demonstrated in a study of the sub-cellular fluorescence spectra of thylakoid membranes in a cyanobacterium, Anabaena PCC7120. It was found that the fluorescence intensity ratio between chlorophyll molecules mainly of photosystem II and phycobilin molecules of phycobilisome (chlorophyll/ phycobilin), in the thylakoid membranes, became lower as one probed deeper inside the cells. This was attributable not to position dependence of re-absorption or scattering effects, but to an intrinsic change in the local physiological state of the thylakoid membrane, with the help of a transmission spectral measurement of sub-cellular domains. The efficiency of the new line-scanning spectromicroscope was estimated in comparison with our own point-by-point scanning spectromicroscope. Under typical conditions of observing cyanobacterial cells, the total exposure time became shorter by about 50 times for a constant excitation density. The improvement factor was proportional to the length of the line-scanned region, as expected. © 2007 The Authors.

Cite

CITATION STYLE

APA

Kumazaki, S., Hasegawa, M., Ghoneim, M., Shimizu, Y., Okamoto, K., Nishiyama, M., … Terazima, M. (2007). A line-scanning semi-confocal multi-photon fluorescence microscope with a simultaneous broadband spectral acquisition and its application to the study of the thylakoid membrane of a cyanobacterium Anabaena PCC7120. Journal of Microscopy, 228(2), 240–254. https://doi.org/10.1111/j.1365-2818.2007.01835.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free