Rapid detection of microorganisms based on active and passive modes of QCM

39Citations
Citations of this article
83Readers
Mendeley users who have this article in their library.

Abstract

Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter) and passive (impedance analyzer) modes of quartz crystal microbalance (QCM) were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo-SMCC was most effective achieving the limit of detection (LOD) 8 × 104CFU·mL−1in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes.

References Powered by Scopus

Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung

9733Citations
N/AReaders
Get full text

Frequency of a Quartz Microbalance in Contact with Liquid

1090Citations
N/AReaders
Get full text

Piezoelectric mass-sensing devices as biosensors - An alternative to optical biosensors?

666Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Piezoelectric biosensors

151Citations
N/AReaders
Get full text

Nano-enabled sensing approaches for pathogenic bacterial detection

94Citations
N/AReaders
Get full text

Electrically-receptive and thermally-responsive paper-based sensor chip for rapid detection of bacterial cells

74Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Farka, Z., Kovář, D., & Skládal, P. (2015). Rapid detection of microorganisms based on active and passive modes of QCM. Sensors (Switzerland), 15(1), 79–92. https://doi.org/10.3390/s150100079

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 38

66%

Professor / Associate Prof. 9

16%

Researcher 7

12%

Lecturer / Post doc 4

7%

Readers' Discipline

Tooltip

Engineering 14

30%

Chemistry 12

26%

Agricultural and Biological Sciences 12

26%

Biochemistry, Genetics and Molecular Bi... 8

17%

Save time finding and organizing research with Mendeley

Sign up for free