Background: To eliminate malaria, surveillance for submicroscopic infections is needed. Molecular methods can detect submicroscopic infections but have not hitherto been amenable to implementation in surveillance programs. A portable loop-mediated isothermal amplification assay called RealAmp was assessed in 2 areas of low malaria transmission. Methods: RealAmp was evaluated in 141 patients from health clinics in India (passive surveillance) and in 127 asymptomatic persons in Thailand (active surveillance). The diagnostic validity, precision, and predictive value of RealAmp were determined using polymerase chain reaction (PCR) as the reference method. A pilot study of Real-Amp was also performed on samples from patients presenting at a Thai health center. Results: A total of 96 and 7 positive cases were detected in India and Thailand, respectively, via PCR. In comparison with nested PCR, the sensitivity and specificity of RealAmp in India were 94.8% (95% confidence interval [CI], 88.3%-98.3%) and 100% (95% CI, 92.1%-100%), respectively, with correct identification of all 5 Plasmodium vivax cases. In Thailand, compared with pooled real-time PCR, RealAmp demonstrated 100% sensitivity (95% CI, 59.0%-100%) and 96.7% specificity (95% CI, 91.7%-99.1%). Testing at the health center demonstrated RealAmp's potential to serve as a point-of-care test with results available in 30-75 minutes. Conclusion: RealAmp was comparable to PCR in detecting malaria parasites and shows promise as a tool to detect submicroscopic infections in malaria control and elimination programs worldwide.

Cited by Powered by Scopus

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

158Citations
N/AReaders
Get full text

Sensitive fluorescence detection of SARS-CoV-2 RNA in clinical samples via one-pot isothermal ligation and transcription

147Citations
N/AReaders
Get full text

Improving pathology and laboratory medicine in low-income and middle-income countries: roadmap to solutions

144Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Patel, J. C., Lucchi, N. W., Srivastava, P., Lin, J. T., Sug-Aram, R., Aruncharus, S., … Meshnick, S. R. (2014). Field evaluation of a real-time fluorescence loop-mediated isothermal amplification assay, realamp, for the diagnosis of Malaria in Thailand and India. Journal of Infectious Diseases, 210(8), 1180–1187. https://doi.org/10.1093/infdis/jiu252

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 34

48%

Researcher 27

38%

Professor / Associate Prof. 6

8%

Lecturer / Post doc 4

6%

Readers' Discipline

Tooltip

Medicine and Dentistry 23

39%

Agricultural and Biological Sciences 16

27%

Engineering 11

19%

Biochemistry, Genetics and Molecular Bi... 9

15%

Save time finding and organizing research with Mendeley

Sign up for free