Uncertainty quantification of bioassay functions for the internal dosimetry of radioiodine

5Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Bioassay functions, which are provided by the International Commission on Radiological Protection, are used to estimate the intake activity of radionuclides; however, they include considerable uncertainties in terms of the internal dosimetry for a particular individual. During a practical internal dose assessment, the uncertainty in the bioassay function is generally not introduced because of the difficulty in quantification. Therefore, to clarify the existence of uncertainty in the bioassay function and provide dosimetrists with an insight into this uncertainty, this study attempted to quantify the uncertainty in the thyroid retention function used for radioiodine exposure. The uncertainty was quantified using a probabilistic estimation of the thyroid retention function through the propagation of the distribution of biokinetic parameters by the Monte Carlo simulation technique. The uncertainties in the thyroid retention function, expressed in terms of the scattering factor, were in the ranges of 1.55-1.60 and 1.40-1.50 for within 24 h and after 24 h, respectively. In addition, the thyroid retention function within 24 h was compared with actual measurement data to confirm the uncertainty due to the use of first-order kinetics in the biokinetic model calculation. Significantly higher thyroid uptakes (by a factor of 1.9) were observed in the actual measurements. This study indicates that consideration of the uncertainty in the thyroid retention function can avoid a significant over- A nd under-estimation of the internal dose, particularly when a high dose is predicted.

References Powered by Scopus

Suppression of Thyroid Radioiodine Uptake by Various Doses of Stable Iodide

96Citations
N/AReaders
Get full text

A physiological systems model for iodine for use in radiation protection

71Citations
N/AReaders
Get full text

Influences of parameter uncertainties within the ICRP-66 respiratory tract model: Particle clearance

32Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Korean-specific biokinetic model for iodine in radiological protection

8Citations
N/AReaders
Get full text

Parameter uncertainty analysis of the equivalent lung dose coefficient for the intake of radon in mines: A review

3Citations
N/AReaders
Get full text

Comparative evaluation of thyroid operational intervention levels depending on age and biokinetic model in nuclear accidents

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kwon, T. E., Chung, Y., Yoo, J., Ha, W. H., & Cho, M. (2020). Uncertainty quantification of bioassay functions for the internal dosimetry of radioiodine. Journal of Radiation Research, 61(6), 860–870. https://doi.org/10.1093/jrr/rraa081

Save time finding and organizing research with Mendeley

Sign up for free