Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties

140Citations
Citations of this article
112Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background Metal-on-metal (MoM) THAs have reduced wear rates compared with metal-on-polyethylene. However, elevated serum metal ion levels and pseudotumors have been reported in large MoM articulations. Questions/purposes We therefore determined (1) if corrosion occurred at the cone/taper interface leading to instability in patients with large-diameter THAs; (2) how patients presented clinically and radiographically; (3) if adverse periprosthetic tissue reactions occurred; (4) whether metal was released from the implants into the periprosthetic tissues; and (5) if head size correlated with metal release. Methods We reviewed 114 patients who had revisions of large-diameter head MoM articulations. Mean time of implantation was 46 months. To identify adverse reactions and particle load, tissues were stained by hematoxylin and eosin and CD3/CD20/CD68 antibodies. Periprosthetic tissues were analyzed for metal content and distribution in different regions. Electrochemical reactions between the stem and adapter were investigated by a minicell electrode. Results Electrochemical studies on the stem and the head adapter showed a risk for galvanic corrosion. Ninety-four percent of patients had instability at the cone/taper interface. All patients presented with early clinical symptoms; 59 patients had radiographic signs of loosening. One hundred four patients had foreign body reactions and necrosis. The largest amounts of metal released were titanium or iron. We found no correlation between head size and metal ion release. Conclusions These findings suggest that in modular cone/ taper connections, friction of the MoM articulations may cause failure of the cone/taper interface leading to galvanic corrosion and loosening. It is unclear whether the design of this MoM system provides sufficient stability at the taper. © The Association of Bone and Joint Surgeons® 2012.

Cite

CITATION STYLE

APA

Meyer, H., Mueller, T., Goldau, G., Chamaon, K., Ruetschi, M., & Lohmann, C. H. (2012). Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. In Clinical Orthopaedics and Related Research (Vol. 470, pp. 3101–3108). Springer New York LLC. https://doi.org/10.1007/s11999-012-2502-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free