The ED50 and ED95 of intrathecal isobaric bupivacaine with opioids for cesarean delivery

84Citations
Citations of this article
99Readers
Mendeley users who have this article in their library.

Abstract

Background; The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED 95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. Methods: After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 μg fentanyl and 200 μg morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. Results: ED 50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. Conclusions: The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric bupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort. © 2005 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc.

Cite

CITATION STYLE

APA

Carvalho, B., Durbin, M., Drover, D. R., Cohen, S. E., Ginosar, Y., & Riley, E. T. (2005). The ED50 and ED95 of intrathecal isobaric bupivacaine with opioids for cesarean delivery. Anesthesiology, 103(3), 606–612. https://doi.org/10.1097/00000542-200509000-00025

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free