App-based Self-administrable Clinical Tests of Physical Function: Development and usability study

32Citations
Citations of this article
97Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Objective measures of physical function in older adults are widely used to predict health outcomes such as disability, institutionalization, and mortality. App-based clinical tests allow users to assess their own physical function and have objective tracking of changes over time by use of their smartphones. Such tests can potentially guide interventions remotely and provide more detailed prognostic information about the participant’s physical performance for the users, therapists, and other health care personnel. We developed 3 smartphone apps with instrumented versions of the Timed Up and Go (Self-TUG), tandem stance (Self-Tandem), and Five Times Sit-to-Stand (Self-STS) tests. Objective: This study aimed to test the usability of 3 smartphone app–based self-tests of physical function using an iterative design. Methods: The apps were tested in 3 iterations: the first (n=189) and second (n=134) in a lab setting and the third (n=20) in a separate home-based study. Participants were healthy adults between 60 and 80 years of age. Assessors observed while participants self-administered the tests without any guidance. Errors were recorded, and usability problems were defined. Problems were addressed in each subsequent iteration. Perceived usability in the home-based setting was assessed by use of the System Usability Scale, the User Experience Questionnaire, and semi-structured interviews. Results: In the first iteration, 7 usability problems were identified; 42 (42/189, 22.0%) and 127 (127/189, 67.2%) participants were able to correctly perform the Self-TUG and Self-Tandem, respectively. In the second iteration, errors caused by the problems identified in the first iteration were drastically reduced, and 108 (108/134, 83.1%) and 106 (106/134, 79.1%) of the participants correctly performed the Self-TUG and Self-Tandem, respectively. The first version of the Self-STS was also tested in this iteration, and 40 (40/134, 30.1%) of the participants performed it correctly. For the third usability test, the 7 usability problems initially identified were further improved. Testing the apps in a home setting gave rise to some new usability problems, and for Self-TUG and Self-STS, the rates of correctly performed trials were slightly reduced from the second version, while for Self-Tandem, the rate increased. The mean System Usability Scale score was 77.63 points (SD 16.1 points), and 80-95% of the participants reported the highest or second highest positive rating on all items in the User Experience Questionnaire. Conclusions: The study results suggest that the apps have the potential to be used to self-test physical function in seniors in a nonsupervised home-based setting. The participants reported a high degree of ease of use. Evaluating the usability in a home setting allowed us to identify new usability problems that could affect the validity of the tests. These usability problems are not easily found in the lab setting, indicating that, if possible, app usability should be evaluated in both settings. Before being made available to end users, the apps require further improvements and validation.

References Powered by Scopus

Using thematic analysis in psychology

110653Citations
N/AReaders
Get full text

Perceived usefulness, perceived ease of use, and user acceptance of information technology

39668Citations
N/AReaders
Get full text

An empirical evaluation of the system usability scale

3281Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Mobile health applications for older adults: A systematic review of interface and persuasive feature design

50Citations
N/AReaders
Get full text

Co-creation with older adults to improve user-experience of a smartphone self-test application to assess balance function

37Citations
N/AReaders
Get full text

Predicting advanced balance ability and mobility with an instrumented timed up and go test

19Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bergquist, R., Vereijken, B., Mellone, S., Corzani, M., Helbostad, J. L., & Taraldsen, K. (2020). App-based Self-administrable Clinical Tests of Physical Function: Development and usability study. JMIR MHealth and UHealth, 8(4). https://doi.org/10.2196/16507

Readers over time

‘20‘21‘22‘23‘24‘2509182736

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 18

42%

Researcher 17

40%

Lecturer / Post doc 5

12%

Professor / Associate Prof. 3

7%

Readers' Discipline

Tooltip

Nursing and Health Professions 12

32%

Computer Science 11

29%

Medicine and Dentistry 10

26%

Engineering 5

13%

Save time finding and organizing research with Mendeley

Sign up for free
0