Aim: To measure the agreement between Schirmer's and phenol red thread tests in detecting dry eyes. Patients and methods: A total of 103 patients attending preoperative cataract assessment clinic who agreed to be involved in the study were recruited. Each patient had one eye examined by both tests in a random order by two different investigators who were unaware of the results of the other test. Dry eye symptoms were assessed using an interviewer-administered questionnaire. The data were collected after the study period and analysed using kappa statistics to assess the agreement between the two tests. Results: Schirmer's test was positive in 25 patients when a cutoff point of 5 mm was used and positive in 41 patients with a cutoff point of 10 mm. Phenol red thread test was positive in four patients when a cutoff point of 10 mm was used and in 32 patients with a cutoff point of 20 mm. Kappa ranged from 0.067 to 0.3 indicating very weak agreement between the two tests. In all, 27% of the patients had symptoms of dry eyes; however, the agreement between each test and the symptoms was very poor. Conclusion: There is very weak agreement between Schirmer's test and phenol red thread tests and between each test and symptoms of dry eyes.
CITATION STYLE
Saleh, T. A., McDermott, B., Bates, A. K., & Ewings, P. (2006). Phenol red thread test vs Schirmer’s test: A comparative study. Eye, 20(8), 913–915. https://doi.org/10.1038/sj.eye.6702052