An improved method for calibrating time-of-flight Laue single-crystal neutron diffractometers

2Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A robust and comprehensive method for determining the orientation matrix of a single-crystal sample using the neutron Laue time-of-flight (TOF) technique is described. The new method enables the measurement of the unit-cell parameters with an uncertainty in the range 0.015-0.06%, depending upon the crystal symmetry and the number of reflections measured. The improved technique also facilitates the location and integration of weak reflections, which are often more difficult to discern amongst the increased background at higher energies. The technique uses a mathematical model of the relative positions of all the detector pixels of the instrument, together with a methodology that establishes a reproducible reference frame and a method for determining the parameters of the instrument detector model. Since all neutron TOF instruments require precise detector calibration for their effective use, it is possible that the method described here may be of use on other instruments where the detector calibration cannot be determined by other means. © 2014 International Union of Crystallography.

References Powered by Scopus

SXD - The single-crystal diffractometer at the ISIS spallation neutron source

146Citations
N/AReaders
Get full text

Nature of the magnetic order in Ca3Co2O6

135Citations
N/AReaders
Get full text

Pulsed spallation neutron sources for slow neutron scattering

128Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ordered magnetism in the intrinsically decorated jeff= 12 α- CoV3 O8

17Citations
N/AReaders
Get full text

A 3D profile function suitable for integration of neutron time-of-flight single crystal diffraction peaks

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Bull, C. L., Johnson, M. W., Hamidov, H., Komatsu, K., Guthrie, M., Gutmann, M. J., … Nelmes, R. J. (2014). An improved method for calibrating time-of-flight Laue single-crystal neutron diffractometers. Journal of Applied Crystallography, 47(3), 974–983. https://doi.org/10.1107/S1600576714006657

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

43%

Professor / Associate Prof. 2

29%

Researcher 2

29%

Readers' Discipline

Tooltip

Physics and Astronomy 5

63%

Agricultural and Biological Sciences 1

13%

Chemistry 1

13%

Materials Science 1

13%

Save time finding and organizing research with Mendeley

Sign up for free