Elevated intrathoracic pressure due to positive end expiratory pressure (PEEP) has the potential for increasing intracranial pressure (ICP) and reducing arterial blood pressure (BP). Such changes could critically reduce cerebral perfusion pressure (CPP = BP - ICP). This possibility was investigated in 15 cats with artificially produced expanding intracranial masses (intracranial balloon). The interrelationships among ICP and central venous and arterial pressures were observed during application and removal of graded levels of PEEP (5, 10, 15 cm H2O). The electroencephalogram and pupillary diameters were monitored. At various levels of ICP, 9 of the cats were given oleic acid intravenously to embolize the lung and cause pulmonary dysfunction. In cats not given oleic acid, PEEP caused a maximal reduction in cerebral perfusion pressure of 45 ± 4 torr (SEM), accompanied by variable changes in ICP. PEEP application in the absence of oleic acid embolization of the lungs caused electroencephalographic abnormalities in 77% of these cats, while pupillary diameters increased in 56%. Animals embolized with oleic acid had significantly less (P <1.5 torr). Abrupt increases in ICP exceeding 11 torr (15 cm H2O) occurred in 4 animals in each group. This happened most frequently (63%) when the intracranial tension before PEEP was above 15 torr. Sudden removal of or reduction in PEEP was accompanied by increases in arterial and intracranial pressures in both groups, although this response was attenuated in the cats given oleic acid. The results indicate a potential for PEEP to evoke neurologic complications in patients who have intracranial disease and that the presence of pulmonary disease may attenuate these deleterious side effects. Monitoring of neurologic function as well as blood gas and cardiovascular effects of PEEP in patients who have intracranial disease is suggested.
CITATION STYLE
Aidinis, S. J., Lafferty, J., & Shapiro, H. M. (1976). Intracranial responses to PEEP. Anesthesiology, 45(3), 275–286. https://doi.org/10.1097/00000542-197609000-00004
Mendeley helps you to discover research relevant for your work.