Medium-term effects of septal and apical pacing in pacemaker-dependent patients: A double-blind prospective randomized study

45Citations
Citations of this article
72Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Pacing the right ventricle is established practice, but there remains controversy as to the optimal site to preserve hemodynamic function. Aims To evaluate clinical and hemodynamic differences between apical and septal pacing in pacemaker-dependent patients. Methods Patients receiving their first pacemaker for advanced atrioventricular block, with the atria in sinus rhythm, were randomized to receive apical (Group A) or septal (Group S) ventricular leads. After implant, with the device programmed VVI 70 beats/min fixed rate, patients underwent a 6-minute walk test and a transthoracic echocardiogram. Then, DDDR was programmed at nominal settings. The same tests were performed at 6 months and 12 months follow-up. If ventricular pacing was less than 98%, the patient was excluded. Results A total of 142 patients were included in the study. During the study year, 71 (50%) were excluded for not fulfilling the condition of 98% ventricular pacing. Groups A and S had 34 and 37 patients, respectively. Age and gender were similar in the groups. At implant, QRS duration was significantly greater in Group A (158 ms) than Group S (146 ms; P = 0.018), and the QRS axis was different: -74.5° in Group A and 1° in Group S (P < 0.001). At 1 year, the 6-minute walk improved significantly in both groups: Group A 15% (P = 0.048) and Group S 24% (P = 0.001). Left ventricular ejection fraction (LVEF) increased from 0.57 to 0.61 (P = 0.008) in Group S, without significant change in Group A. Conclusions After 1 year, pacemaker-dependent patients with septal ventricular leads have better clinical and functional (LVEF) outcome. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Molina, L., Sutton, R., Gandoy, W., Reyes, N., Lara, S., Limón, F., … Moreno, G. (2014). Medium-term effects of septal and apical pacing in pacemaker-dependent patients: A double-blind prospective randomized study. PACE - Pacing and Clinical Electrophysiology, 37(2), 207–214. https://doi.org/10.1111/pace.12257

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free