Aim: To evaluate the impact of the Dexcom G6 continuous glucose monitoring (CGM) device on glycaemic control and cardiometabolic risk in patients with type 2 diabetes mellitus (T2DM) at high cardiovascular risk who are not on insulin therapy. Materials and Methods: Adults with T2DM with glycated haemoglobin (HbA1c) >7% and body mass index (BMI) ≥30 kg/m2 not using insulin were enrolled in a two-phase cross-over study. In phase 1, CGM data were blinded, and participants performed standard glucose self-monitoring. In phase 2, the CGM data were unblinded, and CGM, demographic and cardiovascular risk factor data were collected through 90 days of follow-up and compared using paired tests. Results: Forty-seven participants were included (44% women; 34% Black; mean age 63 years; BMI 37 kg/m2; HbA1c 8.4%; 10-year predicted atherosclerotic cardiovascular disease risk 24.0%). CGM use was associated with a reduction in average glucose (184.0 to 147.2 mg/dl, p
CITATION STYLE
Reed, J., Dong, T., Eaton, E., Friswold, J., Porges, J., Al-Kindi, S. G., … Neeland, I. J. (2024). Continuous glucose monitoring for glycaemic control and cardiovascular risk reduction in patients with type 2 diabetes not on insulin therapy: A clinical trial. Diabetes, Obesity and Metabolism, 26(7), 2881–2889. https://doi.org/10.1111/dom.15608