Simultaneous measurements of local bubble behavior and time averaged local heat transfer at a vertical single tube and a vertical tube bundle were carried out in fluidized beds of different diameters. The evaluation of a theoretical heat transfer equation describing time-averaged heat transfer as a function of solid particle contact time fits the measurements.
CITATION STYLE
Bock, H. J., & Molerus, O. (1980). INFLUENCE OF HYDRODYNAMICS ON HEAT TRANSFER IN FLUIDIZED BEDS. In Journal of Technical Writing and Communication (pp. 217–224). Plenum Press. https://doi.org/10.1007/978-1-4684-1045-7_19