Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity

35Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This paper explores gold nanoparticle (GNP) modified copper oxide nanowires(CuO NWs)based electrode grown on copper foil for non-enzymatic glucose detection in a wide linear ranging up to 31.06 mM, and 44.36 mM at 0.5 M NaOH and 1 M NaOH concentrations. The proposed electrode can be used to detect a very low glucose concentration of 0.3 µM with a high linearity range of 44.36mM and sensitivity of 1591.44 µA mM−1 cm−2. The electrode is fabricated by first synthesizing Cu (OH)2 NWs on a copper foil by chemical etching method and then heat treatment is performed to convert Cu (OH)2 NWs into CuO NWs. The GNPs are deposited on CuO NWs to enhance the effective surface-to-volume ratio of the electrode with improved catalytic activity. The surface morphology has been investigated by XRD, XPS, FE-SEM and HR-TEM analysis. The proposed sensor is expected to detect low-level of glucose in urine, and saliva. At the same time, it can also be used to measure extremely high sugar levels (i.e. hyperglycemia) of ~ 806.5454 mg/dl. The proposed sensor is also capable of detecting glucose after multiple bending of the GNP modified CuO NWs electrode. The proposed device is also used to detect the blood sugar level in human being and it is found that this sensor’s result is highly accurate and reliable.

References Powered by Scopus

Electrochemical glucose biosensors

3082Citations
N/AReaders
Get full text

Effect of aspect ratio and surface defects on the photocatalytic activity of ZnO nanorods

936Citations
N/AReaders
Get full text

An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode

482Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A critical review of electrochemical glucose sensing: Evolution of biosensor platforms based on advanced nanosystems

149Citations
N/AReaders
Get full text

Laser-induced graphene (LIG)-based Au@CuO/V<inf>2</inf>CT<inf>x</inf> MXene non-enzymatic electrochemical sensors for the urine glucose test

80Citations
N/AReaders
Get full text

Flowerlike CuO/Au Nanoparticle Heterostructures for Nonenzymatic Glucose Detection

35Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mishra, A. K., Jarwal, D. K., Mukherjee, B., Kumar, A., Ratan, S., Tripathy, M. R., & Jit, S. (2020). Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity. Scientific Reports, 10(1). https://doi.org/10.1038/s41598-020-67986-4

Readers over time

‘20‘21‘22‘23‘24‘2505101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 11

48%

Researcher 8

35%

Lecturer / Post doc 3

13%

Professor / Associate Prof. 1

4%

Readers' Discipline

Tooltip

Chemistry 13

59%

Materials Science 3

14%

Engineering 3

14%

Medicine and Dentistry 3

14%

Save time finding and organizing research with Mendeley

Sign up for free
0