Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: A two-year prospective study

37Citations
Citations of this article
78Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose. To compare treatment outcome (survival rate, condition of hard and soft peri-implant tissues) and prosthodontic maintenance requirements of two versus three narrow-diameter bone level implants with Locator attachments supporting mandibular overdentures. Materials and Methods. Twenty completely edentulous patients with atrophic mandibles were treated. Ten patients (Group A) were treated with overdentures supported by two narrow (3.3-mm diameter) implants (Straumann AG, Basel, Switzerland) and ten patients (Group B) were treated with overdentures supported by three narrow implants. Locator (Zest Anchors, USA) attachments were used for prosthetic anchorage. Standardized clinical and radiographic parameters (survival rate, plaque index, calculus index, gingival index, bleeding index, probing depth and marginal bone loss) were evaluated at the time of the completion of the prosthetic treatment (baseline) and after 6, 12 and 24 months of functional loading. Prosthodontic maintenance requirements were also scored. Results. Only one implant was lost (Group B) during the healing period. There were no significant differences with regards to any of the studied clinical and radiographic parameters between the two groups (P > 0.05). Few prosthetic complications were recorded. Conclusions. No need to insert more than two narrow-diameter bone level implants with Locator attachments in cases of atrophic mandible to support an overdenture, however, long-term prospective studies are required to support this notion. Copyright © 2012 Ali M. El-Sheikh et al.

References Powered by Scopus

Periodontal disease in pregnancy I. Prevalence and severity

5096Citations
N/AReaders
Get full text

The microbiota associated with successful or failing osseointegrated titanium implants

1725Citations
N/AReaders
Get full text

Effect of implant size and shape on implant success rates: A literature review

221Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Mini vs. standard implants for mandibular overdentures: A randomized trial

88Citations
N/AReaders
Get full text

A 3-year prospective clinical study of telescopic crown, bar, and locator attachments for removable four implant-supported maxillary overdentures

82Citations
N/AReaders
Get full text

The influence of implant diameter on its survival: A meta-analysis based on prospective clinical trials

71Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

El-Sheikh, A. M., Shihabuddin, O. F., & Ghoraba, S. M. F. (2012). Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: A two-year prospective study. International Journal of Dentistry. https://doi.org/10.1155/2012/285684

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 46

90%

Professor / Associate Prof. 5

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 49

91%

Agricultural and Biological Sciences 2

4%

Biochemistry, Genetics and Molecular Bi... 2

4%

Materials Science 1

2%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 1

Save time finding and organizing research with Mendeley

Sign up for free