First experience with chemokine receptor CXCR4 Targeted PET imaging of patients with solid cancers

114Citations
Citations of this article
86Readers
Mendeley users who have this article in their library.

Abstract

CXCR4 is a chemokine receptor that is overexpressed in various human cancers and is involved in tumor metastasis. The aim of this proof-of-concept study was to evaluate a novel CXCR4-targeted PET probe in patients with solid cancers with reported in vitro evidence of CXCR4 overexpression and to estimate its potential diagnostic value. Methods: Twenty-one patients with histologically proven pancreatic cancer, laryngeal cancer, non small cell lung cancer, prostate cancer, melanoma, breast cancer, hepatocellular carcinoma, glioblastoma, sarcoma, or cancer of unknown primary underwent PET imaging using the novel CXCR4 nuclear probe 68Ga-pentixafor. The SUVmax of the liver, spleen, and bone marrow was measured to determine physiologic tracer distribution. For evaluation of tracer accumulation in solid cancers, SUVmax and tumor-tobackground (T/B) ratios were determined in a total of 43 malignant lesions, including 8 primary tumors, 3 locally recurrent tumors, and 32 metastases. When available, the SUVmax of malignant lesions was compared with the corresponding SUVmax measured in routine 18F-FDG PET. Results: Moderate tracer accumulation was detectable in the liver, bone marrow, and spleen, with a mean SUVmax of 3.1, 3.7, and 5.6, respectively. By visual interpretation criteria, 9 of 11 primary and locally recurrent tumors were detectable, exhibiting a mean SUVmax of 4.7 (range, 2.1 10.9) and a mean T/B ratio of 2.9. Twenty of 32 evaluated metastases were visually detectable (mean SUVmax, 4.5 [range, 3.2 13.8]; mean T/B ratio, 2.8). The highest signal was detected in a patient with non small cell lung cancer (SUVmax, 10.9; T/B ratio, 8.4) and a patient with cancer of unknown primary (SUVmax, 13.8; T/B ratio, 8.1). Compared with 18F-FDG PET, which was additionally performed in 10 patients, 68Gapentixafor PET had a lower SUVmax in all measured malignant lesions. Conclusion: On the basis of these first observations in a small and heterogeneous patient cohort, the in vitro CXCR4 expression profile of solid cancers and metastases described in the previous literature does not seem to sufficiently depict the in vivo distribution revealed by CXCR4-targeted PET. Moreover, the detectability of solid cancers seems to be generally lower for 68Ga-pentixafor than for 18F-FDG PET. 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Cite

CITATION STYLE

APA

Vag, T., Gerngross, C., Herhaus, P., Eiber, M., Philipp-Abbrederis, K., Graner, F. P., … Schwaiger, M. (2016). First experience with chemokine receptor CXCR4 Targeted PET imaging of patients with solid cancers. Journal of Nuclear Medicine, 57(5), 741–746. https://doi.org/10.2967/jnumed.115.161034

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free