Rater agreement reliability of the dial test in the ACL-deficient knee

3Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Posterolateral rotatory instability (PLRI) of the knee can easily be missed, because attention is paid to injury of the cruciate ligaments. If left untreated this clinical instability may persist after reconstruction of the cruciate ligaments and may put the graft at risk of failure. Even though the dial test is widely used to diagnose PLRI, no validity and reliability studies of the manual dial test are yet performed in patients. This study focuses on the reliability of the manual dial test by determining the rater agreement. Methods: Two independent examiners performed the dial test in knees of 52 patients after knee distorsion with a suspicion on ACL rupture. The dial test was performed in prone position in 30°, 60° and 90° of flexion of the knees. ≥10° side-to-side difference was considered a positive dial test. For quantification of the amount of rotation in degrees, a measuring device was used with a standardized 6 Nm force, using a digital torque adapter on a booth. The intra-rater, inter-rater and rater-device agreement were determined by calculating kappa (κ) for the dial test. Results: A positive dial test was found in 21.2% and 18.0% of the patients as assessed by a blinded examiner and orthopaedic surgeon respectively. Fair inter-rater agreement was found in 30° of flexion, κF = 0.29 (95% CI: 0.01 to 0.56), p = 0.044 and 90° of flexion, κF = 0.38 (95% CI: 0.10 to 0.66), p = 0.007. Almost perfect rater-device agreement was found in 30° of flexion, κC = 0.84 (95% CI: 0.52 to 1.15), p < 0.001. Moderate rater-device agreement was found in 30° and 90° combined, κC = 0.50 (95% CI: 0.13 to 0.86), p = 0.008. No significant intra-rater agreement was found. Conclusions: Rater agreement reliability of the manual dial test is questionable. It has a fair inter-rater agreement in 30° and 90° of flexion.

Cite

CITATION STYLE

APA

Slichter, M. E., Wolterbeek, N., Auw Yang, K. G., Zijl, J. A. C., & Piscaer, T. M. (2018). Rater agreement reliability of the dial test in the ACL-deficient knee. Journal of Experimental Orthopaedics, 5(1). https://doi.org/10.1186/s40634-018-0131-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free