Abstract

(1) Motivation: Variations in the volume of the residual limb negatively impact various aspects of prosthesis use including the prosthetic socket fit. Although volume adjustment systems mitigate corresponding fit problems to some extent, some users still find the management of these systems challenging. With the ultimate goal of creating a feedback system that assists users with the management of their volume adjustment systems, this study demonstrates the feasibility of detecting variations in the volume of the residual limb. (2) Methods: Measurements of the interface force at the bottom of the prosthetic socket were used as indicators of variations in the volume of the residual limb. Force sensitive resistors (FSRs) were placed at the bottom of participants' prosthetic sockets to monitor the interface limb-socket force as participants walked on a flat surface. Two phases of experiments were carried out: The first phase considered variations simulated by three prosthetic sock plies, established the feasibility of detecting variations in the volume of the limb based on the interface force, and further determined the locations at which the interface force could be used to detect variations in the limb's volume. Having validated the effectiveness of the proposed method in the first phase, the second phase was carried out to determine the smallest detectable variation of the limb's volume using the proposed method. In this phase, variations simulated by one and two prosthetic sock plies were considered. Four and three volunteers with transtibial amputations participated in the first and the second phases, respectively. (3) Results: Results of the first phase showed that an increase in the volume of the limb resulted in a decrease in the force measured at the distal location of the prosthetic sockets of all participants; however, the smallest detected variation could not be statistically confirmed.

References Powered by Scopus

Normality tests for statistical analysis: A guide for non-statisticians

2624Citations
N/AReaders
Get full text

Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050

2148Citations
N/AReaders
Get full text

Residual limb volume change: Systematic review of measurement and management

171Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Adjustable prosthetic sockets: a systematic review of industrial and research design characteristics and their justifications

7Citations
N/AReaders
Get full text

Feasibility testing of a novel prosthetic socket sensor system

5Citations
N/AReaders
Get full text

Transfemoral Osseointegration for Amputees with Well-Managed Diabetes Mellitus

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ahmadizadeh, C., Pousett, B., & Menon, C. (2020). Towards management of residual limb volume: Monitoring the prosthetic interface pressure to detect volume fluctuations-A feasibility study. Applied Sciences (Switzerland), 10(19). https://doi.org/10.3390/app10196841

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

80%

Professor / Associate Prof. 2

20%

Readers' Discipline

Tooltip

Engineering 9

75%

Medicine and Dentistry 1

8%

Business, Management and Accounting 1

8%

Sports and Recreations 1

8%

Save time finding and organizing research with Mendeley

Sign up for free