A multisite randomized trial of portable sleep studies and positive airway pressure autotitration versus laboratory-based polysomnography for the diagnosis and treatment of obstructive sleep apnea: The HomePAP study

296Citations
Citations of this article
222Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Study Objectives: To test the utility of an integrated clinical pathway for obstructive sleep apnea (OSA) diagnosis and continuous positive airway pressure (CPAP) treatment using portable monitoring devices. Design: Randomized, open-label, parallel group, unblinded, multicenter clinical trial comparing home-based, unattended portable monitoring for diagnosis and autotitrating CPAP (autoPAP) compared with in-laboratory polysomnography (PSG) and CPAP titration. Setting: Seven American Academy of Sleep Medicine (AASM) accredited sleep centers. Participants: Consecutive new referrals, age 18 yr or older with high probability of moderate to severe OSA (apnea-hypopnea index [AHI] ≥ 15) identified by clinical algorithm and Epworth Sleepiness Scale (ESS) score ≥ 12. Interventions: Home-based level 3 testing followed by 1 wk of autoPAP with a fixed pressure CPAP prescription based on the 90% pressure from autotitration of PAP therapy (autoPAP) device (HOME) compared with attended, in-laboratory studies (LAB). Measurements: CPAP acceptance, time to treatment, adherence at 1 and 3 mo; changes in ESS, and functional outcomes. Results: Of 373 participants, approximately one-half in each study arm remained eligible (AHI ≥ 15) to continue in the study. At 3 mo, PAP usage (nightly time at pressure) was 1 hr greater: 4.7 ± 2.1 hr (HOME) compared with 3.7 ± 2.4 hr (LAB). Adherence (percentage of night used ≥ 4 hr) was 12.6% higher: 62.8 ± 29.2% compared with 49.4 ± 36.1% in the HOME versus LAB. Acceptance of PAP therapy, titration pressures, effective titrations, time to treatment, and ESS score change did not differ between arms. Conclusions: A home-based strategy for diagnosis and treatment compared with in-laboratory PSG was not inferior in terms of acceptance, adherence, time to treatment, and functional improvements. Trial Registration: http://www.ClinicalTrials.gov; Identifier: NCT: 00642486.

Cite

CITATION STYLE

APA

Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., … Redline, S. (2012). A multisite randomized trial of portable sleep studies and positive airway pressure autotitration versus laboratory-based polysomnography for the diagnosis and treatment of obstructive sleep apnea: The HomePAP study. Sleep, 35(6), 757–767. https://doi.org/10.5665/sleep.1870

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free