In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. © 2011 Wiley Periodicals, Inc.
CITATION STYLE
Lee, J., Kim, K. W., Lee, H., Lee, S. J., Choi, S., Jeong, W. K., … Lee, S. G. (2012). Semiautomated spleen volumetry with diffusion-weighted MR imaging. Magnetic Resonance in Medicine, 68(1), 305–310. https://doi.org/10.1002/mrm.23204
Mendeley helps you to discover research relevant for your work.