Diagnostic Accuracy of Ziehl-Neelsen Smear Microscopy in Comparison with GeneXpert in Pulmonary Tuberculosis: A Multi-Center Study in Kandahar Province, Afghanistan

  • Ahmad M
  • Stanikzai M
  • Rahimy N
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Background: Tuberculosis (TB) is a major global health problem. The early and accurate diagnosis is crucial for disease management and to control disease transmission and the emergence of drug resistance TB. Objectives: This study was carried out to determine the diagnostic accuracy of Ziehl Neelsen (ZN) smear microscopy in comparison with GeneXpert MTB/RIF in pulmonary tuberculosis in Kandahar province, Afghanistan. Methods: This was a facility-based cross-sectional study. We scrutinized TB registers of three health facilities to include patients who had their sputum tested by both ZN smear microscopy and GeneXpert MTB/RIF. We extracted 734 patients’ data registered during January 2019 - June 2020 in a structured form. Kappa value was analyzed using SPSS version 19 software at 95% Confidence Interval (CI). We calculated sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of ZN smear microscopy against GeneXpert MTB/RIF. Results: In comparison with GeneXpert as a reference test, ZN smear microscopy has 67.7% (95% CI:63.44%-70.74%) sensitivity and 100% (95% CI:98.74%-100.00%) specificity. The positive predictive value (PPV) and negative predictive value (NPV) were 100% and 99.89% (95% CI:99.88%-99.90%), respectively. The agreement between ZN smear microscopy and GeneXpert MTB/RIF results was moderate (70.4%) and the Kappa value was 0.45 (95% CI:0.38-0.59). Conclusion: This study has found high specificity but moderate sensitivity for the diagnosis of pulmonary TB using sputum ZN smear microscopy test. Hence, GeneXpert MTB/RIF test is more accurate and reliable for the diagnosis of pulmonary TB.

Cite

CITATION STYLE

APA

Ahmad, M., Stanikzai, M. H., Rahimy, N., Wasiq, A. W., & Sayam, H. (2021). Diagnostic Accuracy of Ziehl-Neelsen Smear Microscopy in Comparison with GeneXpert in Pulmonary Tuberculosis: A Multi-Center Study in Kandahar Province, Afghanistan. Asian Journal of Medicine and Health, 1–7. https://doi.org/10.9734/ajmah/2021/v19i230299

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free