Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: Results from the Reveal LINQ in-office 2 international study

6Citations
Citations of this article
63Readers
Mendeley users who have this article in their library.

Abstract

Background: Historically, the majority of insertable cardiac monitor (ICM) procedures were performed in the cardiac catheterization (cath) lab, electrophysiology (EP) lab, or operating room (OR). The miniaturization of ICMs allows the procedure to be relocated within the hospital without compromising patient safety. We sought to estimate the rate of untoward events associated with procedures performed within the hospital but outside the traditional settings and to characterize resource utilization, procedure time intervals, and physician experience. Methods: The Reveal LINQ in-Office 2 (RIO 2) International study was a single arm, multicenter, prospective study. Patients indicated for an ICM and willing to undergo device insertion outside the cath/EP lab or OR were eligible and followed for 90 days after insertion. Results: A total of 191 patients (45.5% female aged 63.8 ± 26.9 years) underwent successful Reveal LINQ ICM insertion at 17 centers in Europe, Canada and Australia. The median total visit duration was 106 min (interquartile range [IQR]: 55-61). Patient preparation and patient education accounted for 10 min (IQR: 5-20) and 10 min (IQR: 8-15) of total visit duration, respectively. Preparation and education occurred in the procedure room for 90.6 and 60.2% of patients, respectively. There were no untoward events (0.0, 95% CI: 0.0-2.1%) though four patients presented with procedure-related adverse events that did not require invasive intervention. Physicians rated procedure location as convenient or very convenient. Conclusions: The Reveal LINQ™ ICM insertion can be safely and efficiently performed in the hospital outside the cath/EP lab or OR.

Cite

CITATION STYLE

APA

Sanders, P., Piorkowski, C., Kragten, J. A., Goode, G. K., Raj, S. R., Dinh, T., … Rogers, J. D. (2019). Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: Results from the Reveal LINQ in-office 2 international study. BMC Cardiovascular Disorders, 19(1). https://doi.org/10.1186/s12872-019-1106-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free