This case report describes the use of the Micro Vascular Plug (MVP) system in a mural-type vein of Galen aneurysmal malformation, resulting in successful occlusion of the cerebrovascular fistula. This result was confirmed with immediate cessation in blood flow and 6-month follow-up angiography. The unique characteristics of the MVP provide potential advantages over current embolic techniques for occlusion of high-flow, fistulous, intracranial vessels such as those seen in the vein of Galen aneurysmal malformation, and may represent a valuable addition to the currently available options.
CITATION STYLE
Joo, W., Mercier, P., Kheradmand, S., Shirani, P., Sarhan, A., Elbabaa, S. K., & Edgell, R. C. (2017). Vein of Galen malformation treated with the Micro Vascular Plug system: Case report. Journal of Neurosurgery: Pediatrics, 19(6), 729–733. https://doi.org/10.3171/2016.12.PEDS16305